Download Print this page

JLG METRO-MH Operation And Safety Manual page 15

Advertisement

11.
Press the DOWN ARROW to
display a summary of the current
machine settings.
12.
10 seconds before engine start-up
an audible alarm sounds.
13.
At the progammed starting-time the
engine will commence the pre-heat
cycle and, after 5 seconds the
starter-motor cranks the engine.
14.
the controller setting allows the
engine to "warm-up" for 10 seconds.
After completing engine 'warm-up',
15.
each tower light is switched-on
sequenced at 3 second intervals.
Section 1
METRO-MH
MACHINE CONTROLS
16.
17.
• Pushing the Emergency Stop button.
• Opening the trailer canopy.
• Pressing the STOP button on the
• Triggering of the following engine
18.
19.
Page 1-11
The lighting tower will now run in the
AUTO MODE.
The following machine conditions will
cause the lighting tower to shut-
down when running in AUTOMODE.
MH controller.
alarm conditions;
a) low oil pressure
b) low water level
c) high temperature
d) low fuel level
When the COUNTDOWN time has
elapsed all tower lights will be
switched-off in sequence.
The controller will allow the engine
a 20 second cooling cycle before
initiating engine shut-down.
1001206598

Advertisement

loading