LIGHTING TOWER CONTROLLER
OPTIONAL METRO-MH MODULE
Control Panel Push Buttons
Stop/Reset
Stop lighting tower operation
Reset alarm when failure occurs
Lamp test in stop mode
(press for at least three seconds)
Manual Start Mode
Press this key to enter Manual Mode.
Auto Mode
Press this key to enter auto start mode
select interface; use up/down arrow keys
to select mode and press "AUTO" to
confirm selection.
The mode allows automatic control of the
generator. The module
remote start input. On receiving a start
request, the genset starts automatically
and go on-load.
Upon removal of the starting signal, the
module transfers the load from the
generator then shutdown the genset after
the stop delay period and engine cooling
times expire. The module acts on the next
Start event.
Section 1
METRO-MH
MACHINE CONTROLS
monitors
the
Page 1-9
Mute
If an alarm occurs, pressing the mute
button can remove alarm siren, and the
indicator will light up; press the button
again to reset the alarm and the indicator
will turn off. If alarm retriggers in mute
status, the controller cancels mute status.
Strobe Light / Beacon
Switches the beacon light on or off.
(only when the engine is running)
Start
Start lighting tower set in Manual Mode.
Light Off
During running in manual mode, turn off
one light for each press of the button.
Light On
During running in normal manual mode,
turn on one light for each press of the
button.
Menu / Confirm
Press this key to enter menu interface. In
parameter setting interface press this key
to right shift cursor and confirm the setting.
Down/Config
1) Screen Scroll
2) Down cursor and decrease value of
menu setting
Up/Config
1) Screen Scroll
2) Up cursor and increase value of
menu setting.