Sfp991-1Elh200; Sfp992-1 - Siemens SIMATIC NET SFP Series Operating Instructions Manual

Network components
Hide thumbs Also See for SIMATIC NET SFP Series:
Table of Contents

Advertisement

Properties
Receiver input
*
Depending on the cable used, you can find additional information in the "Industrial Ethernet /
)
PROFINET Passive network components" System Manual, see also section "Introduction", paragraph
"Additional documentation".
7.1.4

SFP991-1ELH200

Properties
Transmission mode
Transmission rate
Transmission medium
Light source
Wavelength
Cable length (max.) *
Transmitter output (optical)
Receiver input
*
Depending on the cable used, you can find additional information in the "Industrial Ethernet /
)
PROFINET Passive network components" System Manual, see also section "Introduction", paragraph
"Additional documentation".
7.1.5

SFP992-1

Properties
Transmission mode
Transmission rate
Transmission medium
Light source
Wavelength
Cable length (max.) *
Transmitter output (optical)
Transceiver SFP/SFP+/SCP/STP
Operating Instructions, 10/2019, A5E02630804-13
Sensitivity min.
Input power max.
100Base-LX
100 Mbps (Fast Ethernet)
Single mode fiber-optic cable
Class1-LASER "Eye safe"
1550 nm
200 km
)
Minimum
Maximum
Sensitivity min.
Input power max.
1000Base-SX complying with IEEE 802.3
1000 Mbps (Gigabit Ethernet)
Multimode fiber-optic cable
Class1-LASER "Eye safe"
850 nm
At 50 µm fiber core diameter
)
At 62.5 µm fiber core diameter
Minimum
Maximum
Technical data
7.1 SFP transceiver
-34 dBm
-10 dBm
1 dBm
5 dBm
-42 dBm
-9 dBm
750 m
350 m
-9.5 dBm
-2.5 dBm
31