Sfp991-1Ld/Sfp991-1Ld(C); Sfp991-1Lh - Siemens SIMATIC NET SFP Series Operating Instructions Manual

Network components
Hide thumbs Also See for SIMATIC NET SFP Series:
Table of Contents

Advertisement

Technical data
7.1 SFP transceiver
*) Depending on the cable used:
● If you are using at least OM1 fibers (attenuation ≤ 1.5 dB/km, bandwidth length product ≥
500 MHz*km), you can reach a cable length of up to 3 km.
● When are using fibers with attenuation values ≤ 1 dB/km, you can reach a cable length of
up to 5 km.
You can find additional information in the "Industrial Ethernet / PROFINET Passive network
components" System Manual, see also section "Introduction", paragraph "Additional
documentation".
7.1.2

SFP991-1LD/SFP991-1LD(C)

Properties
Transmission mode
Transmission rate
Transmission medium
Light source
Wavelength
Cable length (max.) *
Transmitter output (optical)
Receiver input
*
Depending on the cable used, you can find additional information in the "Industrial Ethernet /
)
PROFINET Passive network components" System Manual, see also section "Introduction", paragraph
"Additional documentation".
7.1.3

SFP991-1LH+

Properties
Transmission mode
Transmission rate
Transmission medium
Light source
Wavelength
Cable length (max.) *
Transmitter output (optical)
30
100Base-LX complying with IEEE 802.3
100 Mbps (Fast Ethernet)
Single mode fiber-optic cable
Class1-LASER "Eye safe"
1310 nm
26 km
)
Minimum
Maximum
Sensitivity min.
Input power max.
100Base-LX
100 Mbps (Fast Ethernet)
Single mode fiber-optic cable
Class1-LASER "Eye safe"
1550 nm
70 km
)
Minimum
Maximum
-15 dBm
-8 dBm
-28 dBm
-8 dBm
-5 dBm
0 dBm
Transceiver SFP/SFP+/SCP/STP
Operating Instructions, 10/2019, A5E02630804-13