Rack Installation Instructions - IBM Eserver i Series Installation Instructions Manual

Units in a rack
Table of Contents

Advertisement

__ 1. Ensure that you have a current backup of your system (including operating systems, licensed
programs, and data) if you are installing an existing up and running unit in a rack.
__ 2. If you have installed logical partitions on your system unit, refer to Manage logical partitions
in the iSeries Information Center to find instructions on powering down a system with logical
partitions.
__ 3. If an Integrated xSeries Adapter (IXA) is present on the system, shut it down using OS/400
options.
__ 4. Ensure that all jobs are complete.
__ 5. When all jobs are complete, type pwrdwnsys *immed on an iSeries command line and press
Enter.
__ 6. When the iSeries is completely powered down, disconnect all PCs from the system unit.
Power off all devices, such as printers and displays, that are connected to the system unit.
__ 7. Unplug any power cords, such as printers and displays, from electrical outlets.
__ 8. Unplug the system unit and expansion unit power cords from the electrical outlets.

Rack installation instructions

__ 1. Open all boxes that were shipped.
__ 2. Complete the rack unpack instructions that came with the rack. If you are installing the unit in an
existing rack, go to step 7 on page 4.
__ 3. Place the empty rack at the site you identified when completing your planning tasks for your
order.
__ 4. Use the wrench that is provided to lower the front and back stabilizers.
__ 5. CAUTION:
These instructions describe how to install a rack stabilizer to the bottom front of each rack to
prevent the rack from falling over when you slide or pull out the system units. Do not attempt
to slide out or install any system units until the stabilizer is correctly installed. Use caution
when moving the rack and its system units. (RSFTC063)
__ 6. Install the tip plate on the front of the rack.
Install a Model 270, 800, or 810 in a rack
3