Electrostatic discharge

Attach the disposable wrist strap to prevent electrostatic discharge from damaging a device.
video. Attach the adhesive part of the foil to an unpainted surface on the frame of the unit.
Notes:
1. Follow the same precautions you would use without the wrist strap. The 2209 Disposable Wrist Strap
is for static control. It will not increase or decrease your risk of receiving electric shock when using or
working on electrical equipment.
2. Remove the liner from the copper foil at the end when you unroll the strap.
3. Attach the copper foil to an exposed, unpainted metal surface on the frame of the system unit
(electrical ground).
4. Place devices that you remove in electrostatic discharge bags to prevent damage.

Remove covers

Remove the front and side covers.
__ 1. Remove the front cover by gripping the sides of the cover and pulling the cover toward you.
__ 2. Remove the side covers by loosening and removing the two thumbscrews and the two slotted
retainer screws on the back of the system unit. Slide each of the covers from front to back until it
stops.
__ 3. Pull the cover out.
Install a Model 270, 800, or 810 in a rack