Download Print this page
IDEAL VoltAware 61-025 Instruction Sheet

IDEAL VoltAware 61-025 Instruction Sheet

Non-contact voltage (ncv) tester

Advertisement

Available languages

Available languages

Quick Links

ND 6336-1 61-025 VoltAware Ins.
VoltAware™ Non-Contact Voltage (NCV) Tester
Instruction Sheet
IMPORTANT SAFETY INFORMATION
Read and understand all of the instructions and safety information in these operating instructions before
using this tester.
!
WARNINGS
To avoid possible electric shock, personal injury or death follow these guidelines:
• Do not use if green light is not illuminating on tester.
• Do not use if tester appears damaged or is not operating properly.
• Do not use tester for more than the rated voltage on the tester.
• Do not use without the tester fully assembled.
• This tester will not detect the presence of DC voltage.
• This tester will not detect voltages at a distance, such as through walls, metal conduit, or shielded wire.
• Voltage detection maybe affected by outlet design, insulation thickness/type.
• Do not assume that no voltage indication means the circuit is de-energized.
• Voltages below 50VAC will not be detected by the 61-025 but are still shock hazards that can result
in injury or death.
• Use the 3 Point Safety Method. (1) Verify tester operation by measuring a known voltage. (2) Apply tester to circuit under test. (3) Return to the known live voltage again to ensure
proper operation.
• Ensure all fingers are behind finger guard when testing for voltage.
• Replace batteries as soon as low battery is indicated.
• If this tester is used in a manner not specified by IDEAL, protection provided by the product may be impaired.
• Comply with local and national safety requirements, including the use of appropriate personal protective equipment.
Features:
The VoltAware™ NCV tester is useful for identifying hot conductors, finding breaks in wires and detecting the presence of AC voltage at outlets, switches, electrical panels, wires and cables.
• 61-025 model indicates presence of voltage from 50-1000VAC
• 61-026 model indicates presence of voltage from 12-90VAC
• Visual indication of voltage
• Selectable Audible indication of voltage
• Low Battery Indicator
• Sleek, compact design
Operation:
• Twist the tester body to the On position.
• Verify the green light is on.
• Verify tester operation on a known voltage source.
• Place the tip of the tester near an AC voltage source to obtain a voltage indication.
• Voltage presence is indicated by a red, flashing light.
Selectable On/Off for Audible Beeper:
• The tester defaults to the audible ON mode.
• To turn the audible Off, depress the dark gray button.
• To turn the audible back On, depress the button again.
Low Battery Indicator:
• When the battery voltage drops below 2V, the tester indicates the low battery condition by turning off the green light.
Battery Replacement:
• With the tester in the Off position, pull lightly on the two case halves. The tester should separate slightly.
• Then, with little force, twist the two halves away from each other slightly as in the figure. Then, pull the two case
halves apart. Replace with 2 AAA (LR03) batteries.
• Reverse process to re-assemble tester.
Maintenance:
Clean with a damp cloth and mild detergent. If the tester acts erratically, or the green light is not on,
change the batteries.
Service and Replacement Parts:
There are no user-serviceable parts. To inquire about service information, contact IDEAL INDUSTRIES, INC.
at 877-201-9005, or visit our website at www.testersandmeters.com.
Specifications:
Voltage Range:
50-1000VAC (61-025)
12-90VAC (61-026)
Frequency Range:
50-500 Hz
Operating Environment: 32 to 122°F (0 to 51°C)
at <95% R.H.
Storage Temp.:
-4 to 140°F (-20 to 60°C)
at <95% R.H.
Battery:
(2) 1.5V AAA batteries (IEC LR03)
Altitude:
9843 ft. (3000m)
Dimensions:
6.0" (H) x 0.75" (D) [152mm (L) x 19mm (D)]
Weight:
1.6 oz. (46g)
Safety
Complies with UL-61010, EN61010, Cat IV-1000V
C
US
Equipment protected by double insulation.
Instrument complies with insulation overvoltage category IV. Cat IV equipment is designed to protect against transients from primary supply level. Pollution degree 2 in accordance with
1/4/07
12:57 PM
Page 1
N12966
OFF
Cat IV 50-1000VAC
ON
+
+
#61-025
#61-025
OFF
50-1000VAC
OFF
at IV 50-1000VAC
50-1000VAC
ON
ON
#61-025
#61-026
OFF
ON

Advertisement

loading

Summary of Contents for IDEAL VoltAware 61-025

  • Page 1 • Replace batteries as soon as low battery is indicated. • If this tester is used in a manner not specified by IDEAL, protection provided by the product may be impaired. • Comply with local and national safety requirements, including the use of appropriate personal protective equipment.
  • Page 2 • Reemplace la batería tan pronto aparezca el indicador de batería con poca carga. • Si el equipo se utiliza en una forma no especificada por IDEAL, la protección que proporciona puede verse reducida. • Cumpla los requisitos de seguridad locales y nacionales, incluido el uso de equipos de protección personal apropiados.
  • Page 3 • Remplacer la pile dès que le témoin de pile déchargée apparaît. • En cas d'utilisation de cet appareil d'une façon non spécifiée par IDEAL, la protection offerte par ce dernier pourra être compromise. • Se conformer avec toutes les exigences locales et nationales en matière de sécurité, y compris l'utilisation du matériel de protection personnel adéquat.
  • Page 4 Garantie : Ce testeur est garanti à l'acheteur primitif contre tout vice de matière ou de façon pendant deux ans à compter de la date d'achat. Durant cette période de garantie IDEAL INDUSTRIES, INC., à son choix, remplacera ou réparera l'unité défectueuse, suite à la vérification du défaut ou du dysfonctionnement.

This manual is also suitable for:

Voltaware 61-026