Siemens SCALANCE XR-300M PoE Series Compact Operating Instructions page 63

Simatic net. industrial ethernet switches
Table of Contents

Advertisement

Procedure
N
Follow the steps below to fit the connector to a two-wire cable:
1. Connect the cable to the terminal block. Strip the cable jacket only as far as necessary to be
able to strip the insulation and connect up the wires.
2. Feed the supplied cable tie through the two openings in the lower part of the housing as
shown in the figure.
3. Insert the terminal block with the connected cable in the lower part of the housing and
tighten the cable tie. The cable must be securely held in the lower part of the housing by the
cable tie. Cut off the excess cable tie.
4. Fit the upper part of the housing. The housing is correctly mounted when the two catches
audibly click into place and are flush with the surface of the housing.
SCALANCE XR-300M PoE
Compact Operating Instructions, 03/2022, A5E02661178-15
L1
Connecting up
6.7 Power supply
63