Code 163 (Motor-Drive Protection Function Measurement Fault); Code 165 (Signal Fault); Code 181 (Signal Fault, Ptc Input); Code 191 (High Water Level) - Grundfos LC 231 Installation And Operating Instructions Manual

Dual pump unit
Table of Contents

Advertisement

The CIM module is unable to communicate with the product.
Cause
The CIM module is installed incorrectly.
Remedy
Ensure that the module, including cables, is fitted correctly.
Cause
The CIM module is defective.
Remedy
Contact Grundfos.
Related information
2.2.5 Installing a communication interface module
8.21 Code 163 (Motor-drive protection function
measurement fault)
Alarm code 163 is shown on the display.
The alarm symbol on the display turns red, but the pump's
operating mode is unchanged.
Alarm code Motor drive protection function measurement
fault is displayed in Grundfos GO Remote.
Grundfos GO
Input
Remote menu
3 phases without
3 Phase
neutral (L3
connected to N)
3 Phase with
3 phases with
neutral
neutral
2 phases with
2 phase L1-L2-N
neutral
1 phase with
1 Phase L1-N
neutral
Cause
The measured current is above the limit.
Remedy
Make sure that the Mains Power connection setting in
Grundfos GO Remote is configured correctly according to
input connections.
Make sure that the Mains Power connection setting in
Grundfos GO Remote is configured correctly according to
pump connections.
Make sure that the pump is connected to the correct
contactor terminals (T1, T2, T3) depending on the
configuration in Mains Power connection.
Remove load from non-configured contactor terminals (T2,
T3) depending on the configuration in Mains Power
connection.

8.22 Code 165 (Signal fault)

Alarm code 165 is shown on the display.
The alarm symbol on the display turns red and the pump stops.
Alarm code Signal fault is displayed in Grundfos GO Remote.
Cause
The signal from the sensor is out of the configured range.
Remedy
Go to Settings > Level control in Grundfos GO Remote and
ensure that the configured range corresponds to the physical
application type.
Change the sensor, if needed.
Related information
6.6.1 Setting the after-run delay, high level
Output
3-phase pumps connected
to T1-T2-T3.
3-phase pumps connected
to T1-T2-T3.
2-phase pumps: P1
connected to T1-N. P2
connected to T2-N.
1-phase pumps: P1
connected to T1-N. P2
connected to T1-N.

8.23 Code 181 (Signal fault, PTC input)

Alarm code 181 is shown on the display.
The alarm symbol on the display turns red and the pump stops.
Alarm code Signal fault, PTC input is displayed in Grundfos
GO Remote.
Cause
There is a signal fault in the PTC input.
Remedy
Make sure that the two PTC wires from the pump are
connected correctly to the terminals on the product.
Make sure that the third PTC wire is left unconnected, if
present.
Make sure that the PTC wires are undamaged.
Make sure that the PTC sensors within the pumps are
undamaged.
Perform a test by disconnecting the PTC wires from the
pump and shorting PTC1 terminal A and B and also PTC2
terminal A and B, and verify that the error is cleared.
Replace the product due to damaged PTC circuit. Contact
Grundfos.
Related information
2.3.3 Connecting the pump supply and power supply

8.24 Code 191 (High water level)

Alarm code 191 is shown on the display.
The alarm symbol on the display turns red, but the pump's
operating mode is unchanged.
Alarm code High water level is displayed in Grundfos GO
Remote.
Cause
The defined start level did not start the pump.
Remedy
Check and configure the sensor start level.
Cause
The pump is not big enough to remove the water.
Remedy
Contact Grundfos or an authorised service workshop.
Cause
The level sensor is defective and not reacting on level changes.
Remedy
Check the functionality of the level sensor.
Related information
3.6 Configuring the IO terminals using Grundfos GO Remote

8.25 Code 205 (Level switch inconsistency)

Alarm code 205 is shown on the display.
The alarm symbol on the display turns red and the pump
stops.
Alarm code Level switch inconsistency is displayed in
Grundfos GO Remote.
Cause
A float switch could be defective or stuck.
Remedy
Check the functionality of each float switch.
Related information
3.6 Configuring the IO terminals using Grundfos GO Remote
6.6.1 Setting the after-run delay, high level

8.26 Code 220 (Contactor wear out)

Warning code 220 is shown on the display if you press
the Up or Down button.
23