15.12
Changing the combination instrument battery
15.13
Diagnostics connector
Preparatory work
–
Remove the headlight mask with the headlight. (
Main work
–
Remove screws
–
Pull the combination instrument upward out of the holder.
V01807-10
–
Using a coin, turn protection cap
wise and take it off.
–
Remove combination instrument battery
–
Insert the combination instrument with the label facing
upward.
Combination instrument battery (CR 2430) (
–
Check the O-ring of the protection cap for correct seating.
V00371-10
–
Position protection cap
using a coin.
–
Press any button on the combination instrument.
The combination instrument is activated.
–
Position the combination instrument in the holder.
–
Mount and tighten the screws with washers.
V00372-10
Finishing work
–
Install the headlight mask with the headlight. (
–
Check the headlight setting. (
–
Set kilometers or miles. (
–
Set the combination instrument. (
–
Set the clock. (
Diagnostics connector
H00933-12
ELECTRICAL SYSTEM 15
1
with the washers.
2
all the way counterclock-
3
.
2
and turn all the way clockwise
p. 115)
p. 26)
p. 27)
p. 28)
1
is located under the seat.
p. 113)
p. 143)
p. 114)
117