Water Inlet Assy - Bosch T2400S 8 ND 23 Training And Service Information For After Sales

Room sealed fan assisted / pressurized gas water heater for indoor installation
Table of Contents

Advertisement

Pict.21 – Temperature limiter (activation at 85ºC)
The thermal fuse is located around the heat exchanger and for protection is insulated,
nevertheless is composed by 4 specific fuses that melt at 192 ºC in the event of an overheating.
Pict.22 – Thermal Fuse with / without insulation
Pict.23 – Thermal Fuse detail

4.7 Water Inlet Assy

The inlet water valve contains the water connection of ¾" that integrates also the filter and
the flow restrictor according country characteristics.
Flow rate valve / Filter
The inlet water valve contains the filter and is acessible removing screw nº1 and pulling out the
valve with know nº2.
Page 17 from 45
6 720 887 546 "SM FP_ErP LPP-MPP Europe 2018/05 en"