Water Chemistry Requirements; Installation; Inspect Shipment - Bosch GreenTronic 7000 T Installation And Operating Instructions Manual

Hybrid electric water heater
Table of Contents

Advertisement

Installation and Operating Instructions

4.5 Water Chemistry Requirements

NOTICE
Product damage!
Chemical imbalance of the water supply may affect efficiency and cause
severe damage to the appliance and associated equipment. Water quality
must be professionally analyzed to determine whether it is necessary to
treat the water. Various solutions are available to adjust water quality.
Adverse water quality will affect the reliability of the system. In addition,
operating temperatures above 135°F (57 °C) will accelerate the build-up
of lime scale and possibly shorten appliance service life. Failure of an
appliance due to lime scale build-up, low pH, or other chemical imbalance
IS NOT covered by the warranty.
The water must be potable, free of corrosive chemicals, sand, dirt, and other
contaminants. It is up to the installer to ensure the water does not contain corrosive
chemicals or elements that can damage the water heater. Potable water is defined
as drinkable water supplied from utility or well water in compliance with EPA
secondary maximum contaminant levels (40 CFR Part 143.3). If the water contains
contaminants higher than outlined by the EPA, water treatment is required.
If you suspect that your water is contaminated in any way, discontinue use of the
appliance and contact an authorized technician or licensed professional.
Following water chemistry limits must be observed for the water supply:
pH
Hardness
Chlorine Concentration
Total Dissolved Solids
Conductivity μS/cm
Water Chemistry Limits
Table 11
10 |
Value
6.5 to 8.5
5 to 14 Grain/US Gallon
≤ 100 ppm
≤ 500 ppm
≤ 1200
Bosch GreenTronic 7000 T Hybrid Electric Water Heater - BTC 755003301 A (03.2024)

5 Installation

WARNING
Personal injury, property damage!
This water heater must be installed in accordance with all national, state
and local codes and ordinances. If additional information are desired, the
latest edition of the National Electric Code "NFPA 70" are recommended.
This code can be obtained from the National Fire Protection Association at
Battery March Park, Quincy, MA 02269. For Canadian installations, refer
to the Canadian Electric Code (CSA22.1). A copy can be purchased from
the Canadian Standards Association at 5050 Spectrum Way, Mississauga,
ONT L4W 5N6.
Before proceeding with the installation, close the main water supply
valve, open a water faucet to relieve the water pressure, and then close
the faucet.
This water heater is not intended for space heating applications.

5.1 Inspect Shipment

Items included in the packaging:
Hybrid electric water heater
Installation manual
Warranty document
Insulation pipe sleeving (4)
Condensate drain pipe
INSPECT SHIPMENT - for possible damage.
The manufacturer's responsibility ceases upon delivery of goods to the
shipper in good condition. Any claims for damage, shortage in shipments,
or no delivery must be filed immediately against carrier by consignee.
Do not install if the tilt sensor on the outer packaging has tripped.
5.2 Placing the Water Heater
Make sure to read chapter "Getting Started" which provides relevant information to
location, space and drain requirements.
1.
Remove carton box over unit.
2.
Place drain pan.
3.
Lift water heater from the base (foam is bolted to the pallet).
4.
Position water heater to maintain access and clearance requirements.