Bosch T2400S 8 ND 23 Training And Service Information For After Sales page 25

Room sealed fan assisted / pressurized gas water heater for indoor installation
Table of Contents

Advertisement

Overview of ECU (electronic control unit)
1- Ionization electrode (Flame detection)
2- Ignition electrode
3- Transformer
4- Power supply
5- Fan
6- Water flow sensor
7- Water inlet temperature sensor
8- Water outlet temperature sensor
9- HMI
Page 25 from 45
LPP
10- APS (air pressure switch)
11- Segment valve B
12- Segment valve A
13- Gas valve solenoid
14- Safety solenoid valve
15- Temperature limiter (thermostat)
Pict.32 – Electric Diagram LPP circuit board
6 720 887 546 "SM FP_ErP LPP-MPP Europe 2018/05 en"