2. Installation

2.1 Ventilation unit installation site

The ventilation unit can be installed in an attic, machine
room, laundry room, store room, etc.
The installation of the ventilation unit is not recommended
to a wall that borders to a living room or a bedroom due to
the risk of noise.
Ensure easy access to power supply and control cables
and accessories.
The unit can be installed horizontally or vertically. Free
space in front of the maintenance door of the unit must
be at least 1200 mm and above the electrical box at
least 250 mm.

2.1.1 Mounting on the floor

The unit can be installed on the floor. The device is
heavy. Make sure that the mounting base will withstand
its weight. The rear edge of the unit must be at least 50
mm off the wall.
Note! Unit has no condesation drain. Therefore it's not
suitable in houses where unit's extract air humidity may
be high. (i.e. sauna, spa, etc.)