Daikin FTK15JEVM Service Manual page 20

Removal procedure 1.5/2.0/2.5/3.2/3.5/4.6 kw class 9000/12000 btu/h class
Table of Contents

Advertisement

Removal of Swing Motor / PCBs
Step
2
Unfasten the hook, and
disconnect the
connector.
3. Remove the display PCB.
1
Unfasten the hook, and
release the display PCB
ASSY.
Turn over the display
2
PCB ASSY, and
unfasten the 3 hooks to
remove the display
PCB.
3
Disconnect the
connector [S27] from
the display PCB.
The figure shows the
4
component parts of the
display PCB.
18
Procedure
Hook
Hook
ON/OFF button
(Forced cooling operation
[ON/OFF] button)
TIMER lamp
(R8037)
Display PCB ASSY
(R17335)
Display
PCB
(R11653)
[S27]: for control PCB
[S27]
Operation lamp
Signal receiver
(R14848)
Si041051
Points
The connector of the swing
motor has a hook.
Press the hook with a flat
screwdriver to unfasten it.
(R14847)
Removal Procedure