Operation
9. Connect the quick attach couplers (this only applies to
attachments with a quick attach hydraulic system).
Figure 79. Quick Attach Couplers For Hydraulic Systems.
(A) Female Coupler. (B) Male Coupler.
Attachment Removal
NOTE: To remove a standard carriage with forks, spread the
forks apart on the carriage shaft. This provides adequate sup-
port for the carriage to stand alone.
1. Bring the forklift to a complete stop.
2. Move the travel select lever to NEUTRAL (N).
3. Set the parking brake switch to ON (engaged).
4. Extend the boom approximately 18 to 20 inches .
5. With attachment 10 to 12 inches off of the ground, tilt the
attachment backward.
6. Disconnect the quick attach couplers (this only applies to
attachments with a quick attach hydraulic system).
Figure 80. Quick Attach Couplers For Hydraulic Systems.
(A) Female Coupler. (B) Male Coupler.
B
A
B
A
7. Raise the quick attach lock lever.
Figure 81. Quick Attach Lock Lever
8. Pull out the quick attach pin at the bottom of the quick
attach adapter.
Figure 82. Pull Quick Attach Pin from Attachment and
Quick Attach Adapter.
9. Lower the attachment to the ground in a level position.
Figure 83. Lower Attachment to Ground in Level Position