Roger RWL-1 series Operating Manual

Roger RWL-1 series Operating Manual

Wireless lock

Advertisement

Quick Links

Roger Access Control System
RWL-1 Wireless Lock
Operating Manual
Firmware version: 1.1
Document version: Rev. F

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RWL-1 series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Roger RWL-1 series

  • Page 1 Roger Access Control System RWL-1 Wireless Lock Operating Manual Firmware version: 1.1 Document version: Rev. F...
  • Page 2: Design And Application

    RWL-1 Operating Manual.doc 2020-03-25 ESIGN AND APPLICATION RWL-1 lock enables read-in access control based on MIFARE proximity cards. The lock can be operated in Online mode within RACS 5 access control system or in Offline mode as standalone device. In the Online mode the wirelessly connected MC16 controller decides if access is granted. In the Offline mode , based on the card numbers stored in its memory, the lock decides autonomously if the access can be granted.
  • Page 3: Mechanical Construction

    RWL-1 Operating Manual.doc 2020-03-25 Fig. 2. RWL-1 lock in outward opening doors while standing outside Mechanical construction External part of RWL-1 The external part of RWL-1 consists of escutcheon with handle and it is dedicated to installation at the entry to controlled room. The escutcheon includes card reader (A) and hole for door cylinder (G) which can be used for emergency door opening with mechanical key.
  • Page 4 RWL-1 Operating Manual.doc 2020-03-25 Fig. 4. Electronic module inside external escutcheon Internal part of RWL-1 The internal part of RWL-1 consists of escutcheon with handle and it is dedicated to installation at the exit from controlled room. The escutcheon is equipped with knob switch (H) and detector to monitor its status using cable with connector (I).
  • Page 5: Functional Description

    RWL-1 Operating Manual.doc 2020-03-25 Mortise lock The mortise lock includes servomechanism which can be controlled by electronic module located inside external escutcheon. Two groups of wires with plugs come out of the mortise lock. The larger plug (L) is used for connection with internal part of RWL-1 while the smaller plug (K) for connection with external part of RWL-1.
  • Page 6: Proximity Cards

    RWL-1 Operating Manual.doc 2020-03-25 control system. In the Online mode access is controlled by the external controller. Transmission between the lock and controller is wireless and requires intermediary RWH-1 hub. Regardless of the selected working mode (online or offline) the lock requires configuration which can be done from the programming computer with the RogerVDM application and connected to the lock through RUD-1 communication interface.
  • Page 7: Online Mode

    RWL-1 Operating Manual.doc 2020-03-25 lock’s memory even if such Main cards are not physically available (e.g. lost or damaged). Therefore it is recommended to mark and store Backup cards in designated place for future use. Note: Backup card is assigned with same authorizations as accompanying Main card and can be used in the same way as the Main card .
  • Page 8: Led Indicators

    RWL-1 Operating Manual.doc 2020-03-25 2,405 2,445 2,410 2,450 2,415 2,455 2,420 2,460 2,425 2,465 2,430 2,470 2,435 2,475 2,440 2,480 Access granting in Emergency mode Emergency mode enables functioning of access control with wireless locks in case of temporary interferences in radio communication or access control system failure. The access is based on settings saved in lock’s memory.
  • Page 9: Power Supply

    RWL-1 Operating Manual.doc 2020-03-25 · two 2 sec pulses when access is denied · lights steadily when operates in Office mode Orange · lights steadily in case of lock’s configuration error SYSTEM · pulses slowly in case of low battery level (batteries must be replaced) ·...
  • Page 10 RWL-1 Operating Manual.doc 2020-03-25 User adding A. Read ADD programming card. B. Read first card to program user’s Main card . C. Read second card to program user’s Backup card . Notes: · New user shall be granted Office access if step A is repeated twice. ·...
  • Page 11 RWL-1 Operating Manual.doc 2020-03-25 of default list of 50 users with Main cards and Backup cards . The selection of user limit is done with the parameter Backup cards . When the option is set to [1]: Yes then lock operates with 50 users limit. Note: It is recommended to backup RWL-1 settings, save them to file and protect against loss and access of unauthorized persons.
  • Page 12 RWL-1 Operating Manual.doc 2020-03-25 Send to File... Save backup configuration Read from Device Reads configuration from device Send to Device Upload configuration to device Tab: Credentials Adds new user Edit Edit existing user Delete Delete existing user Delete all Delete all users Read from file Read users list from file Write to file...
  • Page 13 RWL-1 Operating Manual.doc 2020-03-25 from the lock’s memory. Once option is set it can be cleared by memory reset procedure only. The purpose of the option is to prevent unauthorized person to read card numbers from the lock’s memory. Default value: No. Don't disturb knob switch When option is set (Yes), rotating the knob switch located on the internal escutcheon will disable access to the room by means of...
  • Page 14 RWL-1 Operating Manual.doc 2020-03-25 Minimal access granting for The parameter specifies the minimal number of access grantings dynamic user list for storing card on dynamic user list. Successive access grantings must be within the time specified by Dynamic user timeout. Default value: 1.
  • Page 15 The parameter Application ID (AID) is located in card’s MAD sector and it specifies the sector where programmable card number (PCN) is stored if the Sector type (see above) is configured as MAD. Default value: 5156 (Roger AID). Block ID The parameter specifies the block number where programmable card number (PCN) is stored in a particular sector of card’s...
  • Page 16: Memory Reset

    RWL-1 Operating Manual.doc 2020-03-25 authorisation. If programmed, the Backup card have the same authorisations as a Main card it accompanies. When user is granted with the Normal access authorisation it can open a door for the time defined by Lock pulse parameter. When user is granted with Office mode it can open the door for unlimited time and then, when required using the same card it can terminate Office mode .
  • Page 17: Specification

    RWL-1 Operating Manual.doc 2020-03-25 Note: Ensure access to metal key to enable emergency opening of the door. Specification Parameter Value Power supply 4 x AA (LR06) alkaline batteries Battery life Approx. 2 years with 10 entries per day Door thickness 38 –...
  • Page 18 Weight of the equipment is specified in the document. Contact: Roger sp. z o.o. sp.k. 82-400 Sztum Gościszewo 59 Tel.: +48 55 272 0132 Fax: +48 55 272 0133 Tech.