Mounting Above A Suspended Ceiling - Cisco AIR-AP1251AG-A-k9 Hardware Installation Manual

Aironet 1250 series
Table of Contents

Advertisement

Chapter 2
Installing the Access Point

Mounting Above a Suspended Ceiling

The access point mounting plate is designed to be integrated into the T-bar grid above the tiles of a
suspended ceiling. Using a T-bar box hanger and bracket mounting clip (not supplied) such as the
Erico 512A with BHC mounting clip, you orient the access point antenna just above the top surface of a
standard ceiling tile. You may need to modify a thicker tile to allow room for the antenna.
It may be helpful to refer to
Figure 2-4
1
2
3
The 1250 series power injector (AIR-PWRINJ4), 1250 series DC power module (AIR-PWR-SPLY1),
Caution
and the antennas have not been tested to UL 2043 and they should not be placed in a building's
environmental air space, such as above suspended ceilings.
OL-8247-02
C I S C O C O N F I D E N T I A L - D r a f t A 1
Figure 2-4
Above Suspended Ceiling Parts
Suspended ceiling T-rail
T-rail clip
Height adjustment screw
before proceeding.
4
T-bar box hanger
5
Bracket mounting clip
Cisco Aironet 1250 Series Access Point Hardware Installation Guide

Mounting Above a Suspended Ceiling

2-11

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Air-lap1251ag-a-k9Air-rm1252a-a-k9Air-rm1252g-a-k9