Cleaning and maintenance
46/64
4.8.2

Low pressure lamps

DANGER!
Danger of burns from hot lamps and surfaces!
Finger and hands may get burned when replacing lamps.
Before carrying out maintenance work, wait until the
device has cooled down sufficiently.
Replace faulty UV low pressure lamps immediately.
Always replace the entire set of lamps after the specified operating time.
Turn 90° and carefully remove from the socket.
UV low pressure lamps possess a reflector which directs the light out-
wards. The lamps must be mounted in such a way that the rear side of
the reflector is located on the device side.
Push the pins vertically into the socket from above.
Turn the lamp 90°.
The lettering must be oriented towards the outside (i.e. towards the tan-
ning room or towards the user).