Toshiba e-STUDIO163 Service Manual page 157

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO163:
Table of Contents

Advertisement

(3)
Take off the damp heater unit or dummy
plate.
P.10-19 "[J] Damp heater unit (DH3) /
Dummy plate"
(4)
Take off the registration roller (metal).
P.10-25 "[Q] Registration roller (metal)"
(5)
Remove 1 screw.
(6)
Take off the registration guide while lifting it
up. Release the latch and take off the drawer
detection switch bracket.
Note:
Be careful not to break the harness which
connects the registration guide unit with the
drawer detection switch when taking off the
unit.
(7)
Take off the bracket of paper empty sensor.
P.10-20 "[K] Paper empty sensor (S7)"
(8)
Release the harness from the harness
clamp, disconnect the connector, remove 3
screws, and then take off the registration
guide.
© 2005 - 2008 TOSHIBA TEC CORPORATION All rights reserved
Fig. 10-53
Registration guide unit
Fig. 10-54
Connector
Fig. 10-55
10 - 27
06/04
Screw
Drawer detection
switch bracket
Registration guide
e-STUDIO163/203
PAPER FEEDING SYSTEM
10