Control Panel Settings Inicontrol 2; List Of Parameters; User Menu - NeOvo Condens EFU C 40 User Manual

Oil-fired condensing boiler
Table of Contents

Advertisement

8

Control panel settings IniControl 2

8.1

List of parameters

Fig.37
1 Sub-menu available
2 Name of the PCB or circuit
Tab.6
List of User sub-menus
Sub-menu
Tab.7
List of parameters in the
Parameter
Description
Heating water flow temperature set point for the zone heated if no
outside temperature sensor has been connected.
For the
Post-operation time of the circuit pump
Can be set from 0 to 20 minutes
Room temperature set point in reduced mode
Can be set from 5 to 30°C
Room temperature set point in comfort mode
Can be set from 5 to 30°C
Do not modify this setting.
Do not modify this setting.
Do not modify this setting.
7642056 - v05 - 30012017
8.1.1
1
2
Description
Main heating circuit
Additional heating circuit B
Additional heating circuit C
Domestic hot water circuit
Central unit PCB CU-OH01
Additional PCB for circuit B
Additional PCB for circuit C
Control panel HMI
/
PCB: Can be set from 7 to 90°C

User menu

3 Setting parameters
Note
CP : Circuits Parameters = Heating circuit parameters
/
sub-menus of the User menu
8 Control panel settings IniControl 2
3
MW-2000435-1
2
Name of the PCB or cir­
cuit
Factory setting
Factory setting
75°C
40°C
3 minutes
4 minutes
16°C
16°C
20°C
20°C
6°C
6°C
21°C
21°C
22°C
22°C
EFU C
25