6 Utilisation with the control panel IniControl 2
Fig.32
6.4

Frost Protection

22
EFU C
4. Select domestic hot water production shut-down by pressing the
MW-5000028-4
5. Confirm by pressing the
6. Go back to the main display by pressing the
6.3.3
It is recommended that the boiler is kept powered on to ensure frost pro­
tection.
If the temperature of the water in the boiler falls too much, the integrated
protection device switches itself on. This device functions as follows:
If the water temperature is lower than 7°C, the circulation pump starts
up.
If the water temperature is lower than 4°C, the boiler starts up.
If the water temperature is higher than 10°C, the boiler shuts down and
the circulation pump continues to run for a short time.
key.
The screen displays:
The frost protection function continues to run.
Production of domestic hot water has been shut down.
Note
Press the
key to restart the appliance: the screen will
display
.
Note
The display disappears after a few seconds of inactivity.
For more information, see
Setting the timer programming, page 31

Shutting down the installation

Caution
The frost protection function does not work if the boiler is powered
off.
Caution
The integrated protection system only protects the boiler, not the
heating system.
Caution
Have the boiler and heating system drained by a qualified profes­
sional if the home is left empty for a long period of time and there
is a chance of frost.
Important
To prevent the radiators and the installation from freezing in pla­
ces where that risk exists (e.g. in a garage or an equipment room),
we recommend the connection of an outside temperature sensor
to the boiler.
.
key.
key.
7642056 - v05 - 30012017