Technical Specifications; Homologations; Certifications; Oil Categories - NeOvo Condens EFU C 40 User Manual

Oil-fired condensing boiler
Table of Contents

Advertisement

3

Technical specifications

3.1

Homologations

Tab.1
Type of oil that can be used
GNR
Non-road diesel with a maximum FAME content of 7 %
Note
To be used exclusively for a boiler fitted with a burner with a heater.
Standard fuel oil
Low-sulphur oil
Bio-oil B10
Mixture of low-sulphur oil (<50 mg/kg) plus 5.9 to 10.9% (in volume) of FAME
Bio-oil B5 (or Bio 5)
Mixture of low-sulphur oil (<50 mg/kg) plus 3 to 5.9% (in volume) of FAME
(1) Liquid petroleum products — Fatty Acid Methyl Esters used as heating fuel
3.2

Technical data

Tab.2
Technical parameters for boiler space heaters
Product name
Condensing boiler
Low-temperature boiler
(1)
B1 boiler
Cogeneration space heater
Combination heater
Rated heat output
Useful heat output at rated heat output and high tem­
perature regime
(2)
Useful heat output at 30% of rated heat output and low
temperature regime
(1)
Seasonal space heating energy efficiency
Useful efficiency at rated heat output and high temper­
ature regime
(2)
Useful efficiency at 30% of rated heat output and low
temperature regime
(1)
Auxiliary electricity consumption
Full load
7642056 - v05 - 30012017
3.1.1

Certifications

The boiler complies with current standards.
CE identification number: 0085CQ0002
3.1.2

Oil categories

(1)
(1)
(1)
Prated
kW
P
kW
4
P
kW
1
ƞ
%
s
ƞ
%
4
ƞ
%
1
elmax
kW
3 Technical specifications
Maximum viscosity
2
6 mm
/s at 20 °C
2
6 mm
/s at 20 °C
2
6 mm
/s at 20 °C
2
6 mm
/s at 20 °C
2
6 mm
/s at 20 °C
EFU C 40
EFU C 50
Yes
Yes
No
No
No
No
No
No
No
No
39
48
38.5
48.2
12.1
15.1
88
89
90.2
90.4
94.8
94.6
0.365
0.379
EFU C