The Distance is inaccurate.
The monitor does not display Application
Rate or Total Volume.
The Total Volume is inaccurate.
The monitor displays 6553.5 when in the
Application Rate setting.
The monitor is erratic in operation.
The displayed measurements do not make
sense.
The monitor reads "OFL."
Possible Cause
1. The speed sensor is not calibrated
correctly.
2. The speed sensor is damaged.
1. The monitor cable is loose.
2. The flow meter is dirty or clogged.
3. The flow meter is not calibrated
correctly.
4. The flow meter is damaged.
1. The flow meter is dirty or clogged.
2. The flow meter is not calibrated
correctly.
3. The flow meter is damaged.
1. The monitor is not receiving data from
the speed sensor.
1. A two-way radio is too close to the
monitor or its cables.
1. The Units of Measurement is set to a
system other than what you expect.
1. The data has exceeded the maximum
allowed.
65
Corrective Action
1. Calibrate the speed sensor.
2. Contact your Authorized Service
Dealer.
1. Connect the monitor cable.
2. Clean the flow meter.
3. Calibrate the flow meter.
4. Contact your Authorized Service
Dealer.
1. Clean the flow meter.
2. Calibrate the flow meter.
3. Contact your Authorized Service
Dealer.
1. Contact your Authorized Service
Dealer.
1. Keep two-way radios away from the
monitor and its cables.
1. Check the Units of Measurement to
ensure that it is set correctly.
1. Press and hold the [Reset] button to
clear the monitor.