Spray Pro™ Monitor
The Spray Pro monitor displays and monitors various
system performance data such as vehicle speed and
application rates. It does not control the application rate.
1. LCD screen
2. Selection dial
3. Total area
4. Speed
5. Units of measure
Monitor Display Selection Dial
Use the dial to set the LCD screen display to the
following:
• Total area
Displays the total acres (US), hectares (SI), or sq feet
(TURF) that you have covered since you last pressed
the Reset calibration button for this setting.
• Speed
Displays the ground speed in miles per hour (if the
Units of Measure is set to US or TURF) or kilometers
per hour (if the Units of Measure is set to SI).
• Units of Measure
Displays the current measurement unit selection as
follows:
– US (United States measuring system)
– SI (metric system)
– TURF (as US but the volumes are in US gallons
per 1000 sq ft instead of US gallons per acre)
6. Application rate
7. Sub Area
8. Distance
9. Sub volume
10. Total volume
The monitor has an LCD screen that displays the data
you select, a selection dial, and 4 buttons for calibrating
the monitor (Figure 20).
Figure 20
11. Reset, calibration button
12. Calibrate, calibration button 17. Width
13. Decrease, calibration
button
14. Increase, calibration button 19. Flowmeter calibration
15. Boom selection
• Application Rate
Displays the application rate in US gallons per acre
(US), liters pre hectare (SI), or US gallons per 1000
sq ft (TURF).
• Sub Area
Displays the total acres (US), hectares (SI), or sq feet
(TURF) that you have covered since you last pressed
the Reset calibration button for this setting, without
affecting the Total Area display. If you press the
Reset calibration button, the Sub Volume resets.
• Distance
Displays the distance you have traveled in feet (US
and TURF) or meters (SI) since you last pressed the
Reset calibration button for this setting.
• Sub Volume
Displays the total volume in US gallons (US and
TURF) or liters (SI) that you have applied since you
last pressed the Reset calibration button for this