Cleanup

Cleanup
Cleaning the sprayer after each use results in
a trouble free start up the next time the
sprayer is used.

Cleaning from a Pail

Pail flushing only works with models that
have a suction tube.
See Cleaning Fluid Compatibility,
page 22 and Static Grounding
Instructions (Oil-Based Materials),
page 23.
1.
Perform Pressure Relief Procedure,
page 12.
2.
Remove spray tip and tip guard assem-
bly from gun and place in waste pail.
ti25832a
3.
Remove suction tube and drain tube
from paint, wipe excess paint off out-
side.
18
4.
Separate drain tube (smaller) from suc-
tion tube (larger).
ti27
7 124a
5.
Place empty waste and flushing fluid
pails side by side.
6.
Place suction tube in flushing fluid. Use
water for water based paint and mineral
spirits or compatible oil-based flushing
solvent for oil-based paint. Place drain
tube in waste pail.
7.
Turn pressure control knob to the
Prime/Clean setting.
8.
Place Prime/Spray valve in PRIME
position.
ti27495a
9.
Turn ON/OFF switch to ON position.
3A3234E