AXIS P5635-E PTZ Mk II Dome Network Camera
Technical Specifications
10–pin Push-Pull System Connector
Function
AC/DC Power
input
Configurable
(Input or Output)
DC Output
GND
Audio Line Out
Audio In

Performance Considerations

When setting up your system, it is important to consider how various settings and situations will affect performance. Some factors
affect the amount of bandwidth (the bit rate) required, others can affect the frame rate, and some affect both. If the load on the
CPU reaches its maximum, this will also affect the frame rate.
The following factors are among the most important to consider:
High image resolution and/or lower compression levels result in images containing more data. Bandwidth affected.
Access by large numbers of Motion JPEG and/or unicast H.264 clients. Bandwidth affected.
Simultaneous viewing of different streams (resolution, compression) by different clients. Effect on frame rate and
bandwidth.
Accessing Motion JPEG and H.264 video streams simultaneously. Frame rate and bandwidth affected.
Heavy usage of event settings affect the product's CPU load. Frame rate affected.
Using HTTPS may reduce frame rate, in particular if streaming Motion JPEG.
Heavy network utilization due to poor infrastructure. Bandwidth affected.
Viewing on poorly performing client computers lowers perceived performance. Frame rate affected.
Pin
Notes
9, 10
The input is polarity independent. Use a Safety Extra Low
Voltage (SELV) compliant limited power source (LPS) with
either a rated output power limited to ≤100 W or a rated
output current limited to ≤5 A.
Digital input – Connect to pin 8 to activate, or leave
3 – I/O 1
floating (unconnected) to deactivate.
5 – I/O 2
6 – I/O 3
Digital output – Connected to pin 8 when activated,
7 – I/O 4
floating (unconnected) when deactivated. If used with an
inductive load, e.g. a relay, a diode must be connected
in parallel with the load, for protection against voltage
transients.
2
Can be used to power auxiliary equipment.
Note: This pin can only be used as power out.
8
Ground for audio and I/O
4
Can be connected to a public address (PA) system or an
active speaker with a built-in amplifier
1
Balanced or unbalanced input for a mono microphone
or line signal
69
Specifications
24 V AC/DC
0 to max 30 V DC
0 to max 30 V DC, open drain,
100 mA
12 V DC
Max load = 50 mA

Advertisement