11.4 BATTERY INSPECTION AND MAINTENANCE

CAUTION: The battery emits flammable and explosive fumes during normal operation. Keep away
from sparks, open flame, and other possible sources of ignition. Always provide adequate ventilation
during charging and maintenance of the battery. The battery contains sulfuric acid (an electrolyte).
Contact with skin or eyes may cause severe burns or blindness. Always wear protective clothing and eye
protection when servicing the battery. The electrolyte is toxic. If swallowed, drink large quantities of
water or milk and seek medical attention immediately, or contact a poison control center.
The battery is located under the seat in the battery compartment.
Battery removal:
• Remove the battery retainer strap
• Disconnect the negative (BLACK) battery lead
first
• Disconnect the positive (RED) battery lead
next
• Use caution when disconnecting lead so as
not to cause a spark
• Remove the battery from the battery
compartment
Testing the battery:
• Measure the battery voltage using a multi-meter
set to Voltage
• A fully charged battery should read 13.0-13.5V. An
under charged or faulty battery will be below
12.0V.
• If the battery is showing under charge condition,
charge the battery using a trickle charger at 7
amps for 10 hours. When charging the battery, it
should be removed from the unit. Connect the
charger lead to the battery before turning on the
charging unit. Turn the charging unit off before
disconnecting the charging leads from the battery.
Retest the battery voltage. If the battery voltage
shows an under charge condition after charging,
replace the battery.
Beamer R2 Rev 1.0
Page 52 of 56
6/13/2007

Advertisement