Configuring SNMP Trap Managers and Traps

Once the FrameSaver unit is connected to the network, SNMP trap managers and
SNMP traps can be configured.
To enter SNMP managers and configure traps:
1. Select SNMP Traps.
Main Menu
SNMP Traps
2. Configure the following:
– Enable SNMP Traps.
– Identify the total Number of Trap Managers.
– Specify the IP address of the NMS(s) to which traps will be sent.
– Specify the Initial Route Destination for the Trap Manager(s).
– Select desired trap categories.
3. Save the configuration.
4. Return to the Main Menu.

Verifying the End-to-End Path

After installation of a remote site unit, run an IP Ping test to ping the NMS at the central
site and verify that the entire path from the remote unit to the NMS is functioning. To run
the IP Ping test, SNMP trap managers must have been configured for the remote unit.
One of those trap managers must be the central site NMS.
1. Select the IP Ping test.
Main Menu
2. Enter the IP Address of the device being pinged, then select Start.
NOTE:
When running tests, the cursor is positioned over the Start command. Press
Enter to start the test. Stop is displayed while the test is running. Press Enter
again to issue the Stop command.
– While the test is running, In Progress... appears in the Status field.
– When the test is finished, Alive. Latency = nn ms should appear as the
Status ( nn being the amount of time the test took in milliseconds).
If any other message is displayed, additional testing will be required.
See Device Messages in Operation and Maintenance of the User's Guide for
information about IP Ping-related messages.
Configuration
Management and Communication
Test
IP Ping
13