Honeywell ADEMCO VISTA-48D Installation And Setup Manual page 35

Table of Contents

Advertisement

FIELD
TITLE and DATA ENTRIES
Auto-Stay Arm
*84
0 = no
1 = partition 1 only
2 = partition 2 only
4 = partition 3 only
Add values for multiple partitions (e.g. for
partitions 1 and 2, enter 3).
Linked Zone Verification Timer
*85
0 = 15 secs
6 = 2-1/2 min #+12 = 8 min
1 = 30 secs
7 = 3 min
2 = 45 secs
8 = 4 min
3 = 60 secs
9 = 5 min
4 = 90 secs
#+10 = 6 min
5 = 2 min
#+11 = 7 min
Up and About Timer: 1-15 hours
See Programming Installer and User
Schedules section for programming
schedules.
Cancel Verify Keypad Display /
*86
AC Fail Dial Delay
Cancel Verify: 0 = no; 1 = yes
AC Fail Dial Delay
0 = random report time between 30 and 60
minutes after fail
1-6 = 10 to 60 minutes in 10-minute
increments (1 = 10 min, 2 = 20 min,
3 = 30 min, 4 = 40 min, 5 = 50 min,
6 = 60 min)
Misc. Fault Delay Time
*87
0 = 15 secs
6 = 2-1/2 min #+12 = 8 min
1 = 30 secs
7 = 3 min
2 = 45 secs
8 = 4 min
3 = 60 secs
9 = 5 min
4 = 90 secs
#+10 = 6 min
5 = 2 min
#+11 = 7 min
*88
Exit Options
0 = all intrusion zones must be intact before
arming
1 = All intrusion zones except in exit path
(zone list 12) must be intact before
arming. Will go into alarm if not restored
at end of exit time
2 = All intrusion zones except in exit path
(zone list 12) must be intact before
arming. Will be bypassed if not restored
at end of exit time
3 = Final contact set: All intrusion zones
except in exit path (zone list 12) must
be intact before arming. Once armed,
exit delay remains on indefinitely until
the last zone, as defined in zone list 8,
is restored; then there is 5-second exit
delay before arming state is active
EXPLANATION
If enabled, the system will automatically change AWAY or MAXIMUM
modes to STAY and INSTANT modes respectively if the entry/exit door
is not opened and closed within the exit delay time after a user arms in
AWAY mode from a wired keypad (non-RF device). An Opening report
followed by an Armed Stay report is sent to the Central Station.
If the door is opened and closed within the exit delay period, the system
remains in AWAY or MAXIMUM mode.
Any RF device that arms the system AWAY overrides this feature and
the system remains armed in the AWAY mode.
NOTE: Must not be used if TeleCommand is used. Does not apply if:
• Final Contact Set exit option (field *88, option 3) is enabled.
• Blockschloss is being used.
Linked Zone Verification Timer (not for use in UL installations):
Sets the maximum amount of time in which two linked zones must be
tripped in an armed system to send an alarm message to the Central
#+13 = 10 min
Station. If only one linked zone is tripped during this time, a trouble
#+14 = 12 min
#+15 = 15 min
message (CID code 380) for that zone is sent to the Central Station.
Assign linked zone pairs in zone list 4.
Up and About Timer: 1-15 hours. This option is part of an Up and
About schedule (event 12) that must be programmed. The value in this
field is the time within which activity must occur within the overall
scheduled up and about time window. If no zones are faulted or no key is
pressed within the selected time period during the scheduled Up and
About time window, a report is sent to the central station. This can
serve as a safety feature for elderly, infirm, or disabled persons.
Cancel Verify Display
When enabled (1 = yes), this feature causes a "CANCELED ALARM"
display on the LCD keypad under the following conditions:
After the kissoff of the cancel message to the Central Station,
indicating a successful transmission.
When an alarm is successfully canceled before the Central Station
received the Alarm message. E.g., if an alarm is falsely triggered and
the user presses code + OFF before the dial delay time has expired,
the message will never go out to the CS.
When the Cancel report is not enabled and the system is disarmed:
a. before dialer delay expires (alarm report not sent) message
"Canceled Alarm" is displayed.
b. after dialer delay expires message "Canceled Alarm" not displayed .
AC Fail Dial Delay: Select the desired report time for AC fail reports.
Used with zones assigned to a configurable zone type with fault delay on
(selected in alarm/trouble processing prompt), and sets a zone response
time of 15 seconds to 15 min. It can be assigned to zones with sensors
#+13 = 10 min
that provide a trouble indication when an oil or gas tank is low, or
#+14 = 12 min
similar applications for critical condition monitoring where a non-alarm
#+15 = 15 min
response is desired and where the zone response time should be very
long to avoid reacting to normal transient faults.
UL: May only be used on non-burglar alarm and non-fire alarm zones
when used on a fire and/or UL burglar alarm installation.
Select the desired option.
NOTE: Must be "0" if system uses zone type 82 - blockschloss.
4-7