4

Commissioning

4
Commissioning
4.1

Standard range permanent pilot models

Fig. 21
Note European Symbols:
OFF
PILOT
ON
30 mm
the pilot flame
36
Correct size
and shape of
35 mm
84/87 only
correct size
and shape of
the pilot flame
4.1.1

Lighting the burner

Caution
Do not operate the water heater until the storage vessel
is completely filled with water, with water running from all
hot taps.
Open the main gas supply cock after all connections to the gas
control are completed and test all connections, using proprietary
leak detection fluid.
1. Remove outer cover and slide inner cover to right. (On 63/62
and 84/87 Models, raise the inspection port cover). Wait for 3
minutes for any unburnt gas to vent.
2. Turn the gas control knob to pilot.
3. Fully depress the gas control knob and the piezo igniter. With
the pilot burner alight, hold gas control knob in for 20
seconds. When gas control knob is released, the pilot
should remain lit. If not, repeat this operation.
4. Close and refit covers.
5. Set temperature indication dial to required temperature as
follows:
Setting
0
Approx. Water
40°C 52°C 62°C 71°C
Temperature
6. Turn the gas control knob to ON and the burner should light.
If not, wait for at least 3 minutes and repeat from step 1.
4.1.2

Shutting Off The Burner

For long periods only (7 days or more) turn gas control knob to
PILOT, depress slightly and turn clockwise to OFF. Turn off the
gas service cock. For shorter periods, leave the heater under
thermostat control.
Note
If the pilot goes out for any reason, turn off heater and
wait for 3 minutes before relighting.