Andrews Model No.
Storage Capacity
Recovery thro' 50°C
Recovery thro' 56°C
Heat Input Gross
Heat Input Net
Gas
Burner Gas Pressure
Max. Gas Input Pressure
Gas Flow Rate
Gas Connection
Flue Gas Temp.
Flue Gas Volume
Gas Injector Orifice Diameter
Flue Size (Secondary)
Cold Water Feed Connection
Hot Water Flow Connection
*Return Connection
Drain Port Size
Max. Working Water Pressure (vented)
Max. Working Water Pressure (unvented) bar
Water Test Pressure
Weight Empty
Weight Full
Shipping Weight
Shipping Dimensions Depth
Shipping Dimensions Width
Shipping Dimensions Height
Issue 2 14/07/16
24/39
I
109
I/h
156
I/h
139
kW
12
kW
11
mbar
10
mbar
35
m
/h
1.12
3
Rc (in BSP Int)
1/2
°C
200
m
/h
17
3
mm
2.95
mm
100
R (in BSP/Exl)
1
R (in BSP/Exl)
1
Rp (in BSP/Exl) 3/4
R (in BSP/Exl)
3/4
bar
10.3
5.5
bar
20.7
kg
43
kg
151
kg
44
mm
546
mm
486
mm
1194
32/40
40/61
63/62
145
182
286
159
243
247
142
217
220
12.5
19
19
11.4
17
17
NATURAL CAT I
H
2
10
10
10
35
35
35
1.16
1.78
1.78
1/2
1/2
1/2
205
195
160
18
26
31
3.05
3.86
3.86
100
100
125
1
1
1
1
1
1
3/4
3/4
3/4
3/4
3/4
3/4
10.3
10.3
10.3
5.5
5.5
5.5
20.7
20.7
20.7
57
65
110
202
247
396
59
68
120
587
587
692
537
537
651
1245
1499
1575
Technical Data
84/87
382
348
311
26
24
10
35
2.43
1/2
125
37
4.22
125
1 1/4
1 1/4
3/4
3/4
10.3
5.5
20.7
181
562
194
914
762
1829
2
9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents