Pilot Inspection - andrews 24/39 Installation And Service Manual

Standard and hiflo ranges - gas fired storage water heaters for natural gas, lpg/butane
Table of Contents

Advertisement

10
Appendix
Condition:
Error code 57: Flame Rod
Shorted to Ground
Disconnect power. Shut off gas
supply to water heater. Slide out
burner assembly (see section on
"removing pilot and main burner
assembly").
Fig. 86
Make sure pilot shield
clears flame sense rod
Flame
sense
rod
Spark
Electrode
96

10.6.2 Pilot inspection

Check to see if pilot shield is
touching pilot flame sensor or
flame sensor touching pilot hood.
Bend shield to prevent interference
or replace pilot shield.
Check pilot flame sense wire for
broken insulation. Replace pilot if
defective
Reinstall pilot and burner
assembly. Reconnect gas line
union, turn on gas.
Check for Gas Leaks
Reconnect power and verify
proper ignitions.