Worcester 12/14 Installation And Servicing Instructions page 9

Conventional flue and room sealed bf; floor standing oil-fired pressure jet appliances
Table of Contents

Advertisement

Fig. 6. Room Sealed Balanced Flue Terminal Installation.
X = 180 mm Maximum
(b) Rear Discharge 7" to 12" Wall.
For use in standard cavity walls and solid walls
up to 327 mm thick. This terminal offers
maximum noise reduction of the flue gases.
This terminal is designed for use with the
extension kit.
X
(a) Rear Discharge 4" to 7" Single Skin Wall.
For use with non-standard/single skin walls up to
182.mm thick.
Where noise emission from the flue terminal is likely to
be of concern, it is recommended that the standard 12 in.
terminal is used and the appliance stood away from the
wall to take up the extra terminal body length.
X = 307 mm Maximum
X
9
X
(c) Rear Discharge Extension Kit
12" to 36" Wall.
For use where the wall thickness exceeds
327.mm or where the appliance is to be stood
away from the wall as shown. The system uses a
standard 12 in. RS Flue Terminal and up to two
extension kits, which simply bolt together.
One extension kit – X = 638 mm Maximum
Two extension kits – X = 952 mm Maximum
270 mm
FLUE GUARD