Worcester 12/14 Installation And Servicing Instructions page 22

Conventional flue and room sealed bf; floor standing oil-fired pressure jet appliances
Table of Contents

Advertisement

Fig. 21. Electro Oil Inter B9B Burner.
(15/19 model)
Combustion Head
A
2 mm
10 mm
Draught tube
Nozzle
Output
Dimension
kW
Head Type
15
PL 6/7/21.5/10
17
PL 6/7/21.5/10
19
PL 6/7/21.5/10
To adjust the nozzle position, undo the
locking screw located at the rear of the
nozzle line and rotate the adjusting
disc one turn anti-clockwise to move
forward by 1 mm.
Fig. 22. Electro Oil Inter B11 Burner.
(20/25 model).
Combustion Head
A
8 mm
Draught tube
Nozzle
Output
Combustion Head
kW
20/25
PL 10/4/24/10 x 78 mm
Spark gap
2-2.5 mm
Photocell
Adjusting
disc
Nozzle block
Pressure Adjustment
Screw
A
3 mm
5 mm
Oil pump
5 mm
Air control indicator
Air adjustment screw
(4mm hexagonal head)
Air adjustment screw
(4 mm hexagonal head)
Spark gap
1 mm
3-3.5 mm
Photocell
Nozzle block
Dimension
A
5 mm
Locking screw
Air control indicator
22
Combustion head
Lockout reset button
Lockout
Pressure
gauge port
reset button
Control box
Pressure
Oil pump
adjustment
screw
Transformer
Control box
Transformer

Advertisement

Table of Contents
loading

This manual is also suitable for:

15/1920/25

Table of Contents