Jenn-Air W10253464B Installation Instructions Manual page 13

30" (76.2 cm) slide-in dual fuel downdraft ranges
Table of Contents

Advertisement

Available languages

Available languages

4. Position blower motor in cabinet opening. Connect vent
system to blower motor outlet using a vent clamp.
A
B
A. 18¾" (47.6 cm) maximum from back
wall forward into cabinet opening
B. Inlet
C. Vent system
D. Vent clamp
E. Wall vent
5. Mount blower motor to the floor with 4 - #8 x ¾" hex head
screws provided.
6. Go to the "Electrical Connection" section.
Floor Venting
1. Mark the floor at the center of the cabinet opening.
2. Position template on floor by matching the centerline of the
template to the centerline drawn on the floor and place
template 2¼" (5.7 cm) from the back wall.
Top View
E
C
D
Top View
3. Determine the correct position for the vent hole, depending on
obstructions (joists) in the floor.
The hole can be cut anywhere within the boundaries of the
larger hatched area.
The blower inlet must face the left side as shown on the
template.
A
A. Inlet from range
B. Exhaust outlet
NOTE: If the template is misplaced, the following
measurements can be used to determine the vent hole
location.
A
A. 9" (22.8 cm)
B. 3¹⁄₈" (7.9 cm)
C. 6³⁄₈" (16.2 cm)
Top View
B
Top View
B
C
D
E
F
D. 2¼" (5.7 cm)
E. 12½" (31.7 cm)
F. 3½" (8.9 cm)
13