Download Print this page
Mitsubishi Electric P-250SB-E Installation Manual

Mitsubishi Electric P-250SB-E Installation Manual

Lossnay heat recovery ventilator system component

Advertisement

Quick Links

LOSSNAY HEAT RECOVERY VENTILATOR SYSTEM COMPONENT
SILENCER BOX
Applicable models
MODEL
P-250SB-E
VL-250CZPVU series
P-350SB-E
VL-350CZPVU series
Installation Manual
■ T his product is for residential use.
■ T he silencer box is for installation between the Lossnay unit and the air duct to reduce the noise of the Lossnay unit.
Do not use it for any other purpose (commercial use, etc.). The incorrect operation may be a cause of a malfunction.
■ T he product must be correctly installed to ensure that its performance and functions are properly demonstrated and to ensure its safe
use and operation. Please read the Installation Manual carefully before installation.
■ F or installation parts, be sure to use accessories and designated parts. Use of non-designated parts may be a cause of malfunction.
■ I nstallation must be performed by dealers and electrical contractors. Incorrect installation may be a cause of a malfunction or
accident. Installation by the customer may result in a malfunction or accident.
■ T he product must be installed indoors.
After completing installation, make sure to give the manual to the user.
● T o ensure correct and safe use, read the Installation Manual thoroughly. Before using the product, check "Safety Precautions" to use
it correctly and safely.
● A fter reading, store the manual in a handy location for easy access.
1. Safety precautions
The following symbols denote the type and degree of danger resulting from incorrect handling.
WARNING
Do not install the product in a place that becomes hot
place, subject to direct sunlight, place with a lot of
oily smoke, or place where organic solvent will get on
the product.
Prohibited
Failure to heed this warning may result in fire.
Refrain from immersing in water or splashing the
product with water.
Failure to heed this warning could result in short circuit or
electric shock.
No water exposure
Do not modify or disassemble the product beyond
that is necessary.
Failure to heed this warning may result in fire, electric
shock or injury.
No disassembly
Do not install Lossnay or the remote controller in a
bathroom or other humid location.
Failure to heed this warning may result in electric shock or
Cannot be installed
electric leakage.
in a bathroom
CAUTION
Wear gloves when installing.
Failure to heed this warning may result in injury.
Securely install parts so that they are not twisted or
deformed.
Injury could result if parts fall.
When installing the product, do not subject the
product to impact: do not drop or throw the product.
Damage to structures inside the product may result in air
or water leakage.
Follow
instructions
Securely install removed parts after inspection.
Injury could result if parts fall.
Do not stand on anything unstable when inspecting,
installing, or removing the parts.
Injury may result if you tumble down.
For use by dealers/contractors
Incorrect handling of the product may result in serious injury or death.
Select a place which is strong enough to support the
product, and install the product securely.
Injury could result if parts fall.
When metal ducts penetrate through metal-sheeted
wooden buildings or structures, install the product
so that there is no electrical contact between the
metal ducts and the metal sheeting.
Electric leakage may cause ignition.
Be sure to turn off the circuit breaker of Lossnay
before inspection.
Failure to heed this warning may result in electric shock
Follow
or injury.
instructions
For installation work parts, be sure to use only
accessories and designated parts.
Use of non-designated parts may result in equipment
damage or accidents.
Incorrect handling of the product may result in injury or damage to
property or household effects.
This appliance is not intended for use by persons
(including children) with reduced physical sensory
or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision
or instruction concerning use of the appliance by a
person responsible for their safety. Children should
be supervised to ensure that they do not play with
the appliance. (This appliance can be used by
children aged from 8 years and above and persons
Follow
with reduced physical, sensory or mental capabilities
instructions
or lack of experience and knowledge if they have
been given supervision or instruction concerning
use of the appliance in a safe way and understand
the hazards involved. Children shall not play with the
appliance. Cleaning and user maintenance shall not
be performed by children without supervision.)
2103876H53401

Advertisement

loading

Summary of Contents for Mitsubishi Electric P-250SB-E

  • Page 1 2103876H53401 LOSSNAY HEAT RECOVERY VENTILATOR SYSTEM COMPONENT SILENCER BOX Applicable models MODEL P-250SB-E VL-250CZPVU series P-350SB-E VL-350CZPVU series Installation Manual For use by dealers/contractors ■ T his product is for residential use. ■ T he silencer box is for installation between the Lossnay unit and the air duct to reduce the noise of the Lossnay unit. Do not use it for any other purpose (commercial use, etc.). The incorrect operation may be a cause of a malfunction. ■ T he product must be correctly installed to ensure that its performance and functions are properly demonstrated and to ensure its safe use and operation. Please read the Installation Manual carefully before installation. ■ F or installation parts, be sure to use accessories and designated parts. Use of non-designated parts may be a cause of malfunction. ■ I nstallation must be performed by dealers and electrical contractors. Incorrect installation may be a cause of a malfunction or accident. Installation by the customer may result in a malfunction or accident.
  • Page 2 2. Outside Dimensions P-250SB-E Pipe guide(SA/EA) Pipe guide(OA/RA) Accessories Wall bracket: 1 Pipe guide(OA/RA) Pipe guide(SA/EA) Wall bracket (accessory) φ Wall mount hook top Heat insulating materials: 4 Wall mount hook center Under fix piece Unit (mm) P-350SB-E Pipe guide(SA/EA) Pipe guide(OA/RA) Pipe guide(/SAEA) Pipe guide(OA/RA)
  • Page 3 2) Apply a good amount of a caulking material (liberally) to 3.1 Installing the wall brackets for the Lossnay the pipe guides and heat insulating materials. Insufficient unit and Silencer box application may cause water leakage and air leakage. Install the wall bracket for the Lossnay unit using the lower four Caulking material (Field supply) holes, and the wall bracket for the Silencer box using the upper four holes. Fix the wall bracket (Included) to the wall, ensuring it is located horizontally. Mark the fixing points through the pre-drilled holes Heat insulating in the bracket, and tighten the screws (normal diameter 4 mm), materials ensuring the interlock side is at the bottom. (Included) Brackets for the Silencer box Pipe guide (Lossnay) 3) Place the Silencer box while aligning the position of the connection ports at the bottom of the Silencer box with the pipe guides of the Lossnay unit. Make sure that the under fix Wall bracket piece of the Silencer box touches the wall mount hook top of (Included) the Lossnay unit. Screw (normal diameter 4 mm) (Field supply) Silencer box Under fix piece (Silencer box) Brackets for the Lossnay unit Wall mout hook top...
  • Page 4 24 hours). tape to peel off.) Indoor humidity can cause condensation because exposed parts can become cold in winter. - Before connecting the ducts, make sure that there are no metal chips or other foreign matter (For example paper or vinyl) Insulating (Field supply) inside the ducts or inside the product. Aluminum tape Duct Inner diameter φ125(P-250SB-E), (Field supply) φ150(P-350SB-E) (Field supply) Note - Attach insulation so that the aluminum tape is not exposed. Pipe guide Caulking material (Product) (Field supply) ■ Post-installation Checks When you have finished installation work, perform trial operation following the installation manual of the Lossnay unit, and check for air leakage or abnormal vibration from the joint parts of the Lossnay unit and silencer box.

This manual is also suitable for:

P-350sb-e