  • Page 1 Home 3P xStorage Home 3P User manual This document is intended for end users...
  • Page 2: Table Of Contents

    3.2 Protection from electric shock .........................10 3.3 Warning decals and rating plate ........................10 General description ..........................11 4.1 xStorage Home 3P high voltage hybrid inverter ....................11 4.2 Operating modes .............................11 4.2.1 “SELF-CONSUMPTION” Mode ......................11 4.2.2 “FEED-IN CONTROL ” Mode ........................12 4.2.3 “BATTERY MANAGER”...
  • Page 3: Introduction

    Home 3P system. All instructions must be read before installing and operating the equipment. This manual should be retained for future reference. Please note that the xStorage Home 3P system must only be installed by Eaton certified personnel, i.e. an Eaton technical support representative or an Eaton certified installer. There are no user serviceable parts inside the xStorage Home 3P system.
  • Page 4: Field Of Applications

    1.1 Field of applications This installation manual is intended for end users. It describes how to securely install and commission the following Eaton xStorage Home three phase (3P) hybrid inverters (Table 1): Table 1 xStorage Home 3P system overview Eaton xStorage Home 3P...
  • Page 5: Conventions Used In This Document

    1.3 Conventions used in this document This manual adopts the following type conventions and acronyms to refer to Eaton xStorage Home system or its parts: Screen type represents information that appears on the screen or LCD display (used to indicate screen content inside the text).
  • Page 6: Figures

    2. PV2 string 3. Battery 4. Emergency power supply (EPS) 5. Interlock system 6. Privileged loads or critical loads 7. Public grid 8. Energy meter 9. Home loads or non-critical loads XSTORAGE HOME 3P USER MANUAL MN700011EN December 2020 www.eaton.com...
  • Page 7 Figure 2. Network connection illustration 1. Dongle Wi-Fi 2. Router 3. Cloud XSTORAGE HOME 3P USER MANUAL MN700011EN December 2020 www.eaton.com...
  • Page 8 Figure 3. Label on the xStorage Home 3P XSTORAGE HOME 3P USER MANUAL MN700011EN December 2020 www.eaton.com...
  • Page 9: Cautions

    Operating range limits: The xStorage Home 3P system can only be used with photovoltaic modules that do not require the earthing of one of the poles. xStorage Home 3P can only be used with photovoltaic modules that meet the specific requirements of class A in accordance with the indications of the IEC 61730 standard.
  • Page 10: Protection From Electric Shock

    106 kPa. The xStorage Home 3P system must be used at a maximum altitude above sea level of 3000 m (9750 feet). For altitudes above 2000 m, due to the rarefaction of the air, specific conditions may occur which must be considered when choosing the place of installation.
  • Page 11: General Description

    4.1 xStorage Home 3P high voltage hybrid inverter The xStorage Home 3P High Voltage (HV) hybrid inverter (see Figure 1) is a DC - AC solar inverter, designed for use in indoor environments. It has been designed to be used in combination with PV panels and connected to the electricity grid and a high voltage (HV) storage battery to optimize self-consumption.
  • Page 12: Feed-In Control" Mode

    This operating mode is mainly indicated in installations where local regulations require a limitation on the energy that is injected in to the grid. Figure 6. Eaton xStorage Home 3P feed in control mode during the day In the presence of sunshine, the energy from the photovoltaic system is used primarily to supply the domestic loads and secondly to charge the battery.
  • Page 13: Battery Manager" Mode

    Figure 8. Eaton xStorage Home 3P battery manager mode during the day In the presence of sunshine, the energy from the photovoltaic...
  • Page 14: Emergency Power Supply (Eps)" Mode

    The total power of the loads connected to the EPS output must be within the range specified in the technical data. If the total load is higher, the xStorage Home 3P will enter in protection mode, disabling the output power and signaling the overload event.
  • Page 15: Backup Reserve" Mode

    Based on the state of health of the battery and to get an accurate and reliable state of charge (SoC) indication, the control module integrated in the battery (BMS) cyclically requests the xStorage Home 3P hybrid inverter to carry out a calibration and to charge up to 100 %.
  • Page 16: Maintenance Charge

    WARNING: The maintenance charge is a safety function of the battery to avoid damages. For this reason, the xStorage Home 3P hybrid inverter can activate grid charging if the available photovoltaic energy is not enough.
  • Page 17: Electrical Connections

    3P system is high enough to allow a stable connection. For this purpose, during the configuration of the network parameters, the scanning and selection of the Wi-Fi network carried out by the xStorage Home 3P reports the signal strength of the wireless network to which you intend to connect: select a network with signal strength S >...
  • Page 18: Control Panel

    • 2 – General alarm LED on: the xStorage Home 3P has detected a fault. The LCD display activates the corresponding alarm icon and shows • the information related to the alarm occurred on the status bar (see the "Troubleshooting" section).
  • Page 19: Dashboard"Page

    Figure 13. The dashboard of xStorage Home 3P display The dashboard screen displays and analyzes in real time all parts of the xStorage Home 3P system. All the power sources supplied to meet the demand of the domestic needs and their operating parameters are constantly monitored and displayed in real time.
  • Page 20: Main Menu

    The parameters as “INSTALLER” profile can be accessed only by Eaton certified installers. Changing the parameters using the installer profile and not being an Eaton certified installer can affect the correct functioning of the system and relieves the manufacturer from all liabilities and invalidates the warranty and/or guarantee.
  • Page 21: Charts Menu

    Figure 16. Day chart from the xStorage Home 3P display The 24 hours chart available from the xStorage Home 3P display is composed by: 1. “CHART SELECTION” key. Press this key to select the different charts (24 hours → 7 days → 12 months).
  • Page 22: 7D" Chart

    Figure 17. Week chart from the xStorage Home 3P display The 7 days chart available from the xStorage Home 3P display is composed by: 1. “CHART SELECTION” key. Press this key to select the different charts (24 hours → 7 days → 12 months).
  • Page 23: Info Menu

    6.5 Info menu The "INFO" menu provides access to general information about the xStorage Home 3P including system parameter, FW version, and network configuration. The data available from the menu are relevant for maintenance and diagnostics. Due to continuous improvement it is possible that changes will be implemented in the future.
  • Page 24: General Menu

    4. “NETWORKING”. This page provides access to the settings to connect the system to a local data network LAN or Wi-Fi. 6.7.1 General menu The "GENERAL" settings menu provides access to all settings relevant to the installation of the xStorage Home 3P . Figure 20. The structure of the general settings menu page The general settings covers: 1.
  • Page 25: System Update

    STAND-BY mode. Make sure you have connected an external USB memory stick where the “ xStorage Home 3P “ update file has been uploaded. The external USB memory stick must be large enough and must have at least 128 Mb of free space.
  • Page 26: Maintenance

    If the operator does not comply with what is described, the manufacturer declines all responsibility. 7.2 Disposal When the xStorage Home system reaches the end of its service life, the end user should contact an Eaton certified installer for disposal instructions.
  • Page 27: Troubleshooting

    8. Troubleshooting This section contains information and procedures for solving possible problems with xStorage Home 3P inverters. Check the warnings or error messages on the system control panel or the error codes on the inverter information panel and act as indicated in the table.
  • Page 28 Contact the grid operator to request approval for the change to the operating limits. If the grid frequency is within the allowed range, but the alarm persists, please contact Eaton technical support representative. XSTORAGE HOME 3P USER MANUAL MN700011EN December 2020 www.eaton.com...
  • Page 29 Converter control system fault. Switch off and restart the system. Refer to the sections “System switching off” and “System switching on” . If the problem persists, please contact Eaton technical support representative. XSTORAGE HOME 3P USER MANUAL MN700011EN December 2020 www.eaton.com...
  • Page 30 EV001LI ÷ Lithium-ion battery messaging from Check visually the connections and polarity at the BATTERY EV0031LI battery BMS. inputs of the system. If the problem persists, please contact Eaton technical support representative. XSTORAGE HOME 3P USER MANUAL MN700011EN December 2020 www.eaton.com...
  • Page 31: Technical Data

    The latest version of the technical datasheet is available for download from the web page www.eaton.com/xstorage. Power derating In order to allow the xStorage Home 3P system to operate in both thermal and electrical safety conditions, the unit automatically reduces the value of the managed power.