Download Print this page

Valve Connection; Wiring Diagrams - Hargrove DEI-PO Installation Manual

Vented gas logs dexen electronic ignition pilot valve

Advertisement

Attach the 49-6-6Z2 (included in the burner accessory kit box) brass fitting to the burner pipe
extending out of the right side of the burner pan (same end that the pilot is mounted on).
Attach the 49-6 into the OUTLET end of the DXMV-C valve.
Attach the FCNW-18 to the 49-6-6Z2 on the end of the pan.
Attach the 49-6 to the INLET (marked IN on the valve body) end of the DXMV-C valve.
Connect the pilot tubing from the DXPI-48 to the elbow fitting on the top of the DXMV-C valve.
Connect the Gas Supply to the 49-6 (on the valve) and to the gas inlet pipe that comes into the
fireplace (connector is included in the Standard Burner Accessory kit box, not this kit).
49-6
(GAS INLET)
PILOT GAS
CONNECTION
Attach the large white plug on the DXWH (wire harness) to the DXICM (I/C Module)
Attach the WHITE wire from the Pilot Assembly to the terminal labeled "I" on the DXICM.
Attach the ORANGE wire from the Pilot Assembly to the terminal labeled "S" on the DXICM.
From the DXWH (wire harness) attach the:
• Orange wire labeled "THTP" to the terminal on the valve labeled "THTP".
• Green wire labeled "TH" to the terminal on the valve labeled "TH".
• Black wire labeled "TP" to the terminal on the valve labeled "TP".
• Red wire labeled "+" to the Red wire on the DXBP (battery pack).
• Black wire labeled "-" to the Black wire on the DXBP (battery pack).
• Brown wires (2) labeled "SWI" to switching device (remote control, wall switch etc.) you will be
using.
TO PILOT

VALVE CONNECTION

49-6-6Z2
(INCLUDED IN BURNER
ACCESSORY KIT)
49-6
(GAS CONNECTION TO
BURNER)

WIRING DIAGRAMS

DXWH-WIRE
HARNESS
AFPI-24
FCNW-18
ORANGE (THTP)
BLACK (TP)
GREEN (TH)
BURNER

Advertisement