7. Controller – Level 2
Program Step
Left tower status
drying
Right tower status
regen.
Left tower
closed
pressure switch
Right tower
closed
pressure switch
Left inlet solenoid
off
Left purge solenoid
off
Right inlet solenoid
off
Right purge solenoid
off
Left inlet valve
open
Left purge valve
closed
Right inlet valve
open
Right purge valve
closed
Temperature display -
none
thermistor location
7.11.1 Test Mode Screen 1 – Step 1
'
TEST MODE STEP 1
OK TO EXIT NOW
No temperature display on this screen.
Press S to advance to screen 2.
7.11.2 Test Mode Screen 2 – Step 2
TEST MODE STEP 2
XX°C XXX°F
The left tower drying light is blinking to indicate the
thermistor location (upper left) that corresponds to the
temperature display.
Press S to advance to screen 3.
7.11.3 Test Mode Screen 3 – Step 3
TEST MODE STEP 3
XX°C XXX°F
The right tower regenerating light is blinking to indicate the
thermistor location (lower right) that corresponds to the
temperature display.
Press S to advance to screen 4.
7.11.4 Test Mode Screen 4 – Step 4
TEST MODE STEP 4
XX°C XXX°F
7. Controller – Level 2
1
2
3
drying
drying
regen.
regen.
closed
closed
closed at start,
closed
open at end
off
off
off
off
on
on
off
on
open
open
closed
closed
closed
closed
closed
open
upper left
lower right

Cycle Sequence Steps

4
5
drying
regen.
regen.
drying
closed
closed
open at start,
closed
closed at end
off
off
off
off
on
off
off
off
open
open
closed
closed
closed
open
closed
closed
upper left
none
Table 7-2
The left tower drying light is blinking to indicate the
thermistor location (upper left) that corresponds to the
temperature display.
Caution: Do not advance to step 5 until the right tower
has fully pressurized.
Press S to advance to screen 5.
7.11.5 Test Mode Screen 5 – Step 5
TEST MODE STEP 5
OK TO EXIT NOW
No temperature display on this screen.
Press S to advance to screen 6.
7.11.6 Test Mode Screen 6 – Step 6
TEST MODE STEP 6
XX°C XXX°F
The right tower drying light is blinking to indicate the
thermistor location (upper right) that corresponds to the
temperature display.
Press S to advance to screen 7.
7.11.7 Test Mode Screen 7 – Step 7
TEST MODE STEP 7
XX°C XXX°F
- 36 –
6
7
regen.
regen.
drying
drying
closed at start,
closed
open at end
closed
closed
on
on
off
on
off
off
off
off
closed
closed
closed
open
open
open
closed
closed
upper right
lower left
8
regen.
drying
open at start,
closed at end
closed
on
off
off
off
closed
closed
open
closed
upper right