Daewoo C-UD121DCEPB Service Manual page 59

Drum washing machine
Table of Contents

Advertisement

6) LACK OF DRY PERFORMANCE
• Situation : after drying, the clothes still get wet.
cause)
The laurdry amount is more than the recommendation capacity 7.0kg.
Condensing cold water is not supplied.
Clogging Bellows Duct results in poor air circulation.
checking method)
part name
BELLOWS
DUCT
VALVE INLET
VALVE INLET
+Condensing
HOSE
• Situation after drying, the clothes was soaked and hot.
cause)
The dry is done from bad spin performance because of unbalance.
no spin was done before the dry had started.
• Situation : PCB shows "H1" or "H3".
cause)
Thermistor is broken.
Thermistor is short or cut-off.
countermeasures)
replace the Thermistor.
checking point
checking results
clogging
bellows duct
BELLOW
DUCT
no water supply
CONDENSING
from inlet valve
HOSE
56
jurge
repair method
heater was
clean the bellow
overheated
duct
owing to poor air
circulation
VALVE INLET
connect normally
connector slipped
out
VALVE INLET
replace valve inlet
broken
ill-connection of
connect normally
condensing hose to
duct pipe

Advertisement

Table of Contents
loading