Esp Curve: Indoor Unit; Technical Specifications: Domestic Hot Water Tank; Test Results In Accordance With En12897 (2016) - Daikin Altherma 3 R F Installer's Reference Manual

Hide thumbs Also See for Altherma 3 R F:
Table of Contents

Advertisement

17
|
Technical data

17.6 ESP curve: Indoor unit

17.7 Technical specifications: Domestic hot water tank

17.7.1 Test results in accordance with EN12897 (2016)

Installer reference guide
294
A (kPa)
100
90
80
70
60
50
40
30
20
10
C D
E
0
0
5
10
15
A External static pressure in the space heating/cooling circuit
B Water flow rate through the unit in the space heating/cooling circuit
C Minimum water flow rate during normal operation
D Minimum water flow rate during backup heater operation
E Minimum water flow rate during cooling operation
F Minimum water flow rate during defrost operation
Notes:
Selecting a flow outside the operating area can damage the unit or cause the unit
to malfunction. See also the minimum and maximum allowed water flow range in
the technical specifications.
Make sure water quality complies with EU directive 2020/2184.
INFORMATION
This unit has been tested and approved according to BS EN12897:2016
Description
EBVH16SU23DJ6V
16 kW
F
20
25
30
35
40
45
Hot water capacity
200 l
50
55
60
B (l/min)
4D128635A
Reheat time
23 min 05 sec
ERLA11~16DAV3+W1 + EBVH16SU23DJ
Daikin Altherma 3 R F
4P655196-1 – 2021.09