17
|
Technical data
17.6 ESP curve: Indoor unit
17.7 Technical specifications: Domestic hot water tank
17.7.1 Test results in accordance with EN12897 (2016)
Installer reference guide
294
A (kPa)
100
90
80
70
60
50
40
30
20
10
C D
E
0
0
5
10
15
A External static pressure in the space heating/cooling circuit
B Water flow rate through the unit in the space heating/cooling circuit
C Minimum water flow rate during normal operation
D Minimum water flow rate during backup heater operation
E Minimum water flow rate during cooling operation
F Minimum water flow rate during defrost operation
Notes:
▪
Selecting a flow outside the operating area can damage the unit or cause the unit
to malfunction. See also the minimum and maximum allowed water flow range in
the technical specifications.
▪
Make sure water quality complies with EU directive 2020/2184.
INFORMATION
This unit has been tested and approved according to BS EN12897:2016
Description
EBVH16SU23DJ6V
16 kW
F
20
25
30
35
40
45
Hot water capacity
200 l
50
55
60
B (l/min)
4D128635A
Reheat time
23 min 05 sec
ERLA11~16DAV3+W1 + EBVH16SU23DJ
Daikin Altherma 3 R F
4P655196-1 – 2021.09