Black (115 VAC) or Brown (230 VAC)
From
White (115 VAC) or Blue (230 VAC)
Line
Power
Green or Yellow (GND)
Figure 2-12 Connecting the 45 VA Transformer on 3-Slot Chassis or NEMA4X
Housing Enclosure
Assembly Instructions for Connecting in NEMA4 Housing Enclosure:
1. Verify that the 45 VA Main Power Transformer voltage matches the line
Voltage. The operating input voltage of the 45 VA transformer is shown
above its primary terminal connection posts.
2. The main power line cable should be inserted into the housing enclosure
through the round opening provided at the bottom of the housing (punch out
the appropriate size hole if necessary).
3. Use the supplied cable connectors to connect the "Live" line wire to the Live
TB and the "Neutral" line wire to the Neutral TB. Refer to Figure 2-13 for the
wire connections.
N
o
t
e
:
N
o
t
e
:
- Verify that the cable wires and connection colors comply with local
standards.
- Use the dedicated grounding strip in the RTU for line ground input.
5. Connect the secondary output of the 45 VA Power Transformer to the Power
Supply Module "PWR IN" inlet using the supplied cable (Motorola p/n:
FKN4463).