Troubleshooting; Warranty - Homewerks 7130-13-BT Manual

Bath fan with bluetooth speaker, led light, and night light
Table of Contents

Advertisement

Available languages

Available languages

TROUBLESHOOTING

PROBLEM
The fan seems louder than it
should.
The fan is not clearing
humidity from the room.
Bluetooth device will not pair
with the fan.
Switch will not power up.
Switch has power, but the
fan does not.
FAN – LIMITED 3-YEAR WARRANTY
If the fan fails due to a defect in materials or workmanship at any time during the first three (3) years of ownership, the manufacturer will
replace it free of charge, postage-paid at their option. This warranty does not cover products that have been abused, altered, damaged,
misused, cut or worn. This warranty does not cover use in commercial applications. Use only manufacturer-supplied genuine warranty
repair replacement parts to repair this fan. Use of non-genuine repair parts will void your warranty. The manufacturer DISCLAIMS all
other implied or express warranties including all warranties of merchantability and/or fitness for a particular purpose. As some states do
not allow exclusions or limitations on an implied warranty, the above exclusions and limitations may not apply. This warranty gives
you specific legal rights, and you may have other rights that vary from state to state.
This warranty is limited to the replacement of defective parts only. Labor charges and/or damage incurred during installation, repair,
replacement as well as incidental and consequential damages connected with the above are excluded. Any damage to this product
as a result of neglect, misuse, accident, improper installation or use other than the purpose SHALL VOID THIS WARRANTY.
Shipping costs for return product as part of a claim on the warranty must be paid for by the customer.
Inquiries regarding warranty claims can be directed to 1-877-319-3757, 7:30 a.m. - 4:30 p.m., CST, Monday - Friday.
BLUETOOTH
®
SPEAKER – LIMITED 1-YEAR WARRANTY
If the BLUETOOTH
®
speaker fails due to a defect in materials or workmanship at any time during the first year of ownership, the
manufacturer will replace it free of charge, postage-paid at their option. This warranty does not cover products that have been abused,
altered, damaged, misused, cut or worn. This warranty does not cover use in commercial applications. Use only manufacturer-supplied
genuine warranty repair replacement parts to repair this fan. Use of non-genuine repair parts will void your warranty. The manufacturer
DISCLAIMS all other implied or express warranties including all warranties of merchantability and/or fitness for a particular purpose. As
some states do not allow exclusions or limitations on an implied warranty, the above exclusions and limitations may not apply. This
warranty gives you specific legal rights, and you may have other rights that vary from state to state.
This warranty is limited to the replacement of defective parts only. Labor charges and/or damage incurred during installation, repair,
replacement as well as incidental and consequential damages connected with the above are excluded. Any damage to this product
as a result of neglect, misuse, accident, improper installation or use other than the purpose SHALL VOID THIS WARRANTY.
Shipping costs for return product as part of a claim on the warranty must be paid for by the customer.
Inquiries regarding warranty claims can be directed to 1-877-319-3757, 7:30 a.m. - 4:30 p.m., CST, Monday - Friday.
Homewerks.com
POSSIBLE CAUSE
The CFM is too great for the space.
The damper is damaged or not working properly.
The bend in the duct is too close to the fan dis-
charge.
The fan discharge is reduced to fit a smaller duct.
The fan body is not attached securely.
There is insufficient airflow intake in the room.
There is insufficient CFM.
NOTE: Using a tissue is not the correct method for
determining if the fan is operating properly. If the fan
clears steam from the room within approximately 15
minutes of completing your shower, then the fan is
operating properly.
Another device is already paired.
There is a wiring issue at the switch, or the power is
not turned on at the fuse box or circuit breaker.
The grille is not receiving a signal from the switch.
Neutral wire connection from the switch to the fan is
not engaging.
SOLUTION
Be sure the CFM rating on the fan matches the
square footage of your room.
Check the damper to ensure it is opening and closing
properly. If the damper has become damaged, please
call Customer Service.
Be sure you do not have any sharp bends in the duct
within 18 in. of the fan discharge.
Use the recommended size ducting to reduce fan
noise.
Be sure the fan is securely attached to the ceiling
joists.
Be sure a door or window is slightly ajar or open to
allow airflow. The fan is not able to draw air out of the
room without enough airflow.
Be sure the CFM rating of the fan matches the
square footage of your room.
Make sure BLUETOOTH
devices.
Check the wiring diagram on Page 5 and confirm
wiring is correct. Verify the power is turned on.
Turn off power. Disconnect the grille for 5 seconds, then
reconnect the grille and test. Repeat as necessary.
Run a dedicated neutral wire from the switch to the
fan. Consult an electrician if necessary.
11
signal is turned off on other
®

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

Table of Contents