3

Technical Data

Parameter
Front panel, W x H x D 285 x 177 x 6 mm
Mounting depth
Front panel seal
Rear panel seal
Keyboard material
Reverse side material
Weight
Serial port RS422/
RS485
Serial port RS232C
Ethernet
USB
CF-slot
Flash memory for
application
Real time clock
Real time clock
battery
Power consumption at
rated voltage
Display
Active area of display,
W x H
Fuse
Power supply
Ambient temperature
Storage temperature
Relative humidity
CE approvals
UL, cUL approvals
(when procuct or
packing is marked)
DNV
NEMA
* See section
Chemical Resistance
Mitsubishi Electric, MA00776C
56 mm (156 mm including clearance)
IP 66
IP 20
Membrane switch keyboard with metal domes. Overlay film
of Autotex F157 * with print on reverse side. 1 million
operations.
Powder-coated aluminum
1.4 kg
25-pin D-sub contact, chassis-mounted female with
standard locking screws 4-40 UNC.
9-pin D-sub contact, male with standard locking screws 4-40
UNC.
Shielded RJ 45
Host type A (USB 1.1), max output current 500mA
Device type B (USB 1.1)
Compact flash, type I and II
12 MB (incl. fonts)
±20 PPM + error because of ambient temperature and supply
voltage. Total maximum error: 1 min/month at 25 °C
Temperature coefficient: 0.004 ppm/°C
CR2450 (UL and cUL: Sanyo or Panasonic)
Minimum lifetime: 3 years
Normal: 0.4 A
Maximum: 0.9 A
TFT-LCD. 640 x 480 pixels, 64K color.
CCFL backlight lifetime at the ambient temperature of
+25 °C: >50,000 h.
131.5 x 98.6 mm
Internal DC fuse, 3.15 AT, 5 x 20 mm
+24V DC (20 - 30V DC). Power supply connector.
CE: The power supply must conform with the requirements
according to IEC 60950 and IEC 61558-2-4.
UL and cUL: The power supply must conform with the
requirements for class II power supplies.
Vertical installation: 0 ° to +50 °C
Horizontal installation: 0 ° to +40 °C
-20 ° to +70 °C
5 - 85 % non-condensed
Noise tested according to EN61000-6-4 emission and
EN61000-6-2 immunity.
UL 1604 Class I, Div 2 / UL 508 / UL 50 4x indoor use only
Yes
4x indoor use only