Figure 2-8. Connecting the Fibre Channel cable to the SAN Access Module
Part Description
2-meter multi-mode Fibre Channel cable
5-meter multi-mode Fibre Channel cable
15-meter multi-mode Fibre Channel cable
30-meter multi-mode Fibre Channel cable
50-meter multi-mode Fibre Channel cable
Multi-mode shortwave GBIC
Configuring the SAN Access Module through SSP
The Option ROM Configuration Array (ORCA) cannot be used to configure
logical drives through the SAN Access Module. Configuration of logical
drives through the SAN Access Module requires access to a 64-Bit/66-MHz
Fibre Channel Host Adapter with the Array Configuration Utility (ACU),
Version 2.50A or higher.
Selective Storage Presentation (SSP) allows logical disk drives on an array
controller to be shared by multiple servers. At POST, ORCA identifies
SCSI-attached logical drives available to the host bus adapter in the server. For
more information on ORCA, refer to "Configuring Your Array" in the
Compaq StorageWorks SA5300 Controller User Guide.
Table 2-1
Multi-Mode Fibre Channel Cables and GBIC
Installation and Connection Guidelines 2-9
Option Kit Number
234457-B21
234457-B22
234457-B23
234457-B24
234457-B25
380561-B21
Need help?
Do you have a question about the StorageWorks SAN Access Module and is the answer not in the manual?
Questions and answers