Table Of Contents; Indication To The Manual; Description Of Product - Brinkmann SBA141 Operating Instructions Manual

Table of Contents

Advertisement

Brinkmann-Horizontal End Suction Pumps Series SBA141...143, SBF125
Contents
1
Indication to the manual .................................... 2
2
Description of product .................................... 2-3
3
Safety instructions .......................................... 3-4
4
Transport and storage ....................................... 4
5
Installation and Connection ............................ 4-5
6
Start up / Shut down .......................................... 5
7
Operation ........................................................... 5
8
Servicing and Maintenance ............................... 6

1 Indication to the manual

This operating manual gives basic instructions
which are to be observed during installation, opera-
tion and maintenance of the pump. It is therefore
imperative that this manual be read by the respon-
sible personnel and operator prior to assembly and
commissioning. It is always to be kept available at
the installation site.
1.1
Identification of safety instructions in the
operating manual
Safety instructions given in this manual non-
compliance with which would affect safety are
identified by the following symbol
Safety sign according with
ISO 3864-B.3.1
or where electrical safety is involved, with:
Safety sign according with
ISO 3864-B.3.6
Where non-compliance with the safety instructions
may cause a risk to the machine and it's function
the word
ATTENTION
is inserted.

2 Description of product

2.1
General description of the pump
Pumps of this type are one or multi-stage centrifu-
gal inline pumps with a compact design where the
impellers are fixed on the driving shaft extension.
The pump shaft and motor shaft are interconnected
by means of a shaft clamp. These pumps are fitted
out with semi-open impellers and a suction screw in
order to minimize the risk of cavitations.
SBA pumps are equipped with a single mechanical
seal. The SBF Pumps are equipped with double
mechanical seal.
These pumps are for horizontal installations next to
or underneath a tank. The pumps are foot mounted
and must be screwed down in order to ensure a
secure stance.
BE8140
9 Trouble shooter's guide ..................................... 6
10 Spare part ......................................................... 7
11 Repair Instructions ........................................ 8-9
12 Disposal ............................................................ 9
13 EC declaration of conformity ........................... 10
2.2
Intended use
These pumps are not self-priming and must be
gravity fed. They are designed to handle water-
soluble coolants as well as cutting oils within the
limiting application in accordance with table 1.
Limit of Application (Table 1)
Type
Mediums
Kinetic viscosity
of the medium
Temperature of
medium
Particle-size in
the medium
min. delivery
volume
Dry running
Switching-on
frequency per
hour
Ambient tem-
perature
Set-up altitude
The pumps are to be operated within their design
limits. Applications outside of these limits are not
approved. The manufacturer is not responsible for
any damages resulting from use of the pumps in
such applications.
Edition 10/2021
SBA, SBF
Coolants, cooling- and cutting-
oils
2
...45 mm
/s
0 ... 80 °C
2.5 mm SBA141...143
5 mm SBF
1% of Q max.
Dry running causes increased
wear and should be avoided.
During the test of the direction of
rotation (< 30 s) permissible.
Motors less 3 kW max. 200
40 °C
1000 m