Brinkmann Immersions pumps of the series KTF16 ... 83 Contents Indication to the manual ........2 8 Servicing and Maintenance ....... 6 9 Trouble shooter’s guide ........7 Description of product ........2-3 Safety instructions ..........4 10 Spare part ............8 Transport and storage ........
Page 3
Technical data Number of Max. del. Max. del. Height Depth of Weight Power Noise stage pressure volume immersion 50 / 60 level bar / spec. Type weight 1 l/min H mm h mm dBA / 50 Hz KTF16 / 120 0.32 0.045 KTF25 / 120...
Safety instructions relevant for opera- 3 Safety instructions tion When operating the pump, the safety instructions contained in this manual, the relevant national • If hot or cold machine components involve accident prevention regulations and any other hazards. they must be guarded against acci- service and safety instructions issued by the plant dental contact.
5 Installation and Connection Electric wiring Mechanical installation During any assembly or disassembly process the pumps must be secured against tipping trough ropes for example at all times. Pumps must be mounted securely. Piping, tank and All service work must be carried out by quali- pumps must be mounted without any tension.
6 Start up / Shut down Start up ATTENTION Attention! Potential Risk of Burning! Switch off at the mains. Surface temperatures above 50°C do occur After connection the electrical wires, close the terminal box. Briefly start the motor (max. 30 sec.) during regular operation of the single-phase pumps, i.e.
9 Trouble shooter’s guide Fault Cause Remedy Motor does not start. no motor At least two of the power supply Check fuses, terminals and supply noise leads have failed leads . Overload has tripped Inspect overload Motor does not start, humming noise One of the supply leads has failed See above Impeller faulty...
10 Spare part 10.1 Spare part list for the immersion pumps of the series KTF16 ... 83 Item Description Stator with terminal board End shield / KTF54, 55, 83 Terminal box Fan cover Ball bearing DIN 625 Ball bearing DIN 625 Gasket 10 Slotted cheese head screw DIN 84...
Manufacturer Brinkmann Pumpen, K. H. Brinkmann GmbH & Co. KG Friedrichstraße 2 D-58791 Werdohl Germany This declaration of conformity is issued under the sole responsibility of Brinkmann Pumps and belongs to the following product. Product name Immersion pumps KTF16…KTF83 Type The named product described above complies with the following statutory requirements of United Kingdom: UK SI 2008 No.
Page 10
EC declaration of conformity / Déclaration de conformité CE / Declaración de conformidad CE Hersteller / Manufacturer / Constructeur / Fabricante Brinkmann Pumpen, K. H. Brinkmann GmbH & Co. KG Friedrichstraße 2, D-58791 Werdohl Produktbezeichnung / Product name / Désignation du produit / Designación del producto Tauchpumpen / Immersion pumps / Pompes plongeantes / Bombas de inmersión...
Need help?
Do you have a question about the KTF16 Series and is the answer not in the manual?
Questions and answers