Brinkmann Immersions pumps of the series STA/SAL901 ... 1303 Contents 9 Trouble shooter’s guide ........7 Indication to the manual ........2 Description of product ........2-4 10 Spare part ............8-9 Safety instructions .......... 4-5 11 Repair ............... 9 Transport and storage ........
Page 3
Technical data Max. del. Max. del. Height Depth of Weight Power Noise pressure bar / volume immersion 60 Hz level 1, 2) Type Type spec. weight 1 l/min H mm h mm g kg dBA / 50 Hz STA901 / 200 SAL901 / 220 / 300...
Max. del. Max. del. Height Depth of Weight Power Noise pressure bar / volume immersion 60 Hz level 1, 2) Type Type spec. weight 1 l/min H mm h mm g kg dBA / 50 Hz STA1302 / 290 SAL1302 / 310 1600 / 390 / 410...
Safety instructions relevant for mainte- nance, inspection and assembly work Any work on the machine shall only be performed when it is at a standstill, it being imperative that the procedure for shutting down the machine described in this manual be followed. Pumps and pump units which convey hazardous media must be decontaminated.
6 Start up / Shut down Electric wiring Start up ATTENTION Switch off at the mains. All service work must be carried out by quali- After connection the electrical wires, close the fied service personnel. Pump must be discon- terminal box. Briefly start the motor (max. 30 sec.) nected from the power source and all rotating and check the rotation according to the arrow on parts must stand still.
8 Servicing and Maintenance ATTENTION The surface of the motor must be kept free of dirt. The motor shaft is spinning in permanently greased ball bearings (with special grease and increased bearing play) and does not require any special maintenance. 9 Trouble shooter’s guide Fault Cause...
10 Spare part 10.1 Spare part list for the immersion pumps of the series STA/SAL901 ... 1303 Item Description Stator with terminal board Motor flange End shield Terminal box up to 5.0 kW Terminal box frame up 6.0 kW Terminal box cover up 6.0 kW Fan cover Ball bearing DIN 625...
11.2 Assembling the insert shaft and motor 10.2 Indications to the spare part order shaft Spare parts are available from the supplier. Standard commercially available parts are to be ATTENTION purchased in accordance with the model type. Clean the contact surfaces of the insert shaft (2) The ordering of spare parts should contain the (inside) and the motor shaft (3).
EC declaration of conformity / Déclaration de conformité CE / Declaración de conformidad CE Hersteller / Manufacturer / Constructeur / Fabricante Brinkmann Pumpen, K. H. Brinkmann GmbH & Co. KG Friedrichstraße 2, D-58791 Werdohl Produktbezeichnung / Product name / Désignation du produit / Designación del producto Tauchpumpen / Immersion pumps / Pompes plongeantes / Bombas de inmersión...