Advertisement

Quick Links

HORIZONTAL MULTISTAGE CENTRIFUGAL MONOBLOCK
HORIZONTAL MULTISTAGE CENTRIFUGAL MONOBLOCK
INSTALLATION / SPARE PARTS MANUAL
INSTALLATION / SPARE PARTS MANUAL
FOR MODELS :
FOR MODELS :
AQUAPUMP INDUSTRIES
AQUAPUMP INDUSTRIES
TUDIYALUR POST, COIMBATORE - 641 034, INDIA
TUDIYALUR POST, COIMBATORE - 641 034, INDIA
E-mail : marketing@aquagroup.in
E-mail : marketing@aquagroup.in
AHS SERIES
AHS SERIES
'TEXMO'
'TEXMO'
AHS 02/03, AHS 02/06
AHS 02/03, AHS 02/06
AHS 04/04
AHS 04/04
MANUFACTURED BY :
MANUFACTURED BY :
Website : www. aquagroup.in
Website : www. aquagroup.in
'AQUATEX'
'AQUATEX'
AHS 04/06
AHS 04/06
AHS 04/08
AHS 04/08

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TEXMO AHS 02/03 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Aqua TEXMO AHS 02/03

  • Page 1 HORIZONTAL MULTISTAGE CENTRIFUGAL MONOBLOCK HORIZONTAL MULTISTAGE CENTRIFUGAL MONOBLOCK AHS SERIES AHS SERIES INSTALLATION / SPARE PARTS MANUAL INSTALLATION / SPARE PARTS MANUAL ‘AQUATEX’ ‘AQUATEX’ FOR MODELS : FOR MODELS : ‘TEXMO’ ‘TEXMO’ AHS 04/06 AHS 04/06 AHS 02/03, AHS 02/06 AHS 02/03, AHS 02/06 AHS 04/08 AHS 04/08...
  • Page 2 Dear Customer, Please follow the instructions given in this manual to install and maintain our “Horizontal Multistage Centrifugal monoblock” pumpset to get reliable operation. When you order spares in future, please inform the name plate detail, viz., serial number, pump type and other datas. Spare parts list of the pumpset is given in this manual for your reference.
  • Page 3: Suction Pipe

    TEXMO / AQUATEX HORIZONTAL MULTISTAGE CENTRIFUGAL MONOBLOCK INSTALLATION: LOCATION: The pumpset should be erected in a place relatively free from dust , fumes , and moisture. SUCTION PIPE: The vertical distance between the water level at the suction side and the pumpset should not exceed 26 feet (8 meters).
  • Page 4: Delivery Pipe

    DELIVERY PIPE: Use same diameter delivery pipe as in delivery bracket to avoid excess pressure loss. TECHNICAL DATA: ELECTRICAL DATA: Please check the power supply voltage and frequency corresponds to the pumpset name plate specification and connect according to diagram shown in terminal box cover.
  • Page 7: Spare Parts List

    SPARE PARTS LIST PART PART NAME QUANTITY MATERIAL NUMBER CAST IRON SUCTION BRACKET MS (ZINC COATED) 2 - 2 TIE ROD MS ( ZINC COATED) 2 – 3 TIE ROD NUT CAST IRON DELIVERY BRACKET STAGE CASING STAGE – 1(Upto 4 Stages) SS, AISI 304 STAGE –...
  • Page 8 SPARE PARTS LIST PART PART NAME QUANTITY MATERIAL NUMBER 11 – 11 BACK COVER & MOTOR FRAME MS ( ZINC COATED) HEXAGONAL BOLT 11 - 15 CAPACITOR WITH CLAMP 1 (for 0.5 & 1 HP) 2 (for 1.5 & 2 HP) 11 –...
  • Page 9 OVERALL DIMENSION CHART SIZE SI.NO TYPE SUCTION x DELIVERY (mm) (mm) (mm) TEXMO AHS 02/03 380.0 200.0 190.0 1” x 1” (BSP) AHS 02/06 500.0 200.0 190.0 1 1/4” x 1 1/4” (BSP) AHS 04/04 450.0 200.0 190.0 AQUATEX AHS 04/06 530.0 230.0 196.0 1 1/4”...
  • Page 10: Warranty Card

    WARRANTY FOR MONOBLOCK : Aquapump Industries warrants to the purchaser of this TEXMO / AQUATEX product, that for a period of 12 months commencing from the date of purchase of the product, Aquapump Industries will repair or replace free of charge any part or parts of the product, should Aquapump Industries be fully satisfied in its sole discretion, that the defect/s is / are due to faulty material or workmanship only.